The MicroNet Plus Expansion Chassis may use either single or redundant power supplies.
Each power supply module produces three regulated outputs:
24 V @ 12 A (max), 5 V @ 32 A (max, derated above
55 degree C external ambient temperature), and 5 V Precharge @ 3 A (max).
A motherboard located on the back of the chassis provides the
interconnection of the three outputs from each power supply module
into three corresponding power busses: 24 V bus, 5 V bus, and 5 V precharge bus.
The 24 V and 5 V busses are load shared between the two power supply modules.
The 5 V precharge bus is not load shared.
Power output regulation at the motherboard, including line, load, and temperature effects,
is less than ±10% for the 24 V bus, +/-5% for the 5 V bus,
and +/-10% for the 5 V Precharge bus.
The 5 V and 5 V Precharge busses are not for external use.
The 24 V bus is accessible from the motherboard for
external use (protected by 5 A fuses on the source and return lines).
When redundant power supplies are running, current sharing circuitry balances the load to reduce heat
and improve the reliability of the power supplies.
In the event that on supply needs to be replaced, the recommended method for changing
Power Modules is with the power off (to the module being removed and the module being inserted).
The system will tolerate this “cold swap” method without failure.
Each main power supply has four LEDs to indicate power supply health (OK, Input Fault,
Overtemperature, and Power Supply Fault).
See MicroNet Plus Power Supply Troubleshooting (Section 5.5) for a description of the LED indications.
Input power connections are made to the power supply through a plug/header assembly on the front of
the power supply.
Woodward | 8273-1013 | 2301E-ST – Steam Turbine Control 8273-1013 | |||
Woodward | 8273-1014 | 2301E-ST – Steam Turbine Control, Hazardous Location Zone 2 8273-1014 | |||
Woodward | 8237-2046 | 2301E-HT – Hydro Turbine Control (Francis), 24 VDC, Ordinary Location 8237-2046 | |||
Woodward | 8200-1400 | 505HT – LVDC, Pelton Turbines 8200-1400 | |||
Woodward | 8200-1401 | 505HT – HVAC/DC, Pelton Turbines 8200-1401 | |||
Woodward | 8200-1402 | 505HT – LVDC, Francis / Kaplan Turbines 8200-1402 | |||
Woodward | 8200-1403 | 505HT – HVAC/DC, Francis / Kaplan Turbines 8200-1403 | |||
Woodward | 8269-1073 | 17” TouchPanel OCP – Includes RemoteView Software Program 8269-1073 | |||
Woodward | 8928-5311 | RemoteView - Software License 8928-5311 | |||
Woodward | 5404-1801 | Old 505 to New 505 Retrofit Wiring Kit 5404-1801 | |||
Woodward | 8200-1500 | Peak200 – Bulkhead Mount, LV 8200-1500 | |||
Woodward | 8200-1501 | Peak200 – Bulkhead Mount, HV 8200-1501 | |||
Woodward | 8200-1502 | Peak200 – Bulkhead Mount, LV, ATEX Zone 2 8200-1502 | |||
Woodward | 8200-1503 | Peak200 – Front Panel Mount, LV 8200-1503 | |||
Woodward | 8200-1504 | Peak200 – Front Panel Mount, HV 8200-1504 | |||
Woodward | 8200-1505 | Peak200 – Front Panel Mount, LV, ATEX Zone 2 8200-1505 | |||
Woodward | 8200-1508 | Peak200 – Bulkhead Mount, HV, Class1 Div2 Haz. Loc. Compliant 8200-1508 |