Using the comparison guide
Important notice
This guide is intended for limited distribution to ABB’s channel
partners and customers who are replacing the ACH550 drive
with the ACH580 HVAC drive. ABB has prepared this document
to aid sales associates, authorized channel partners and
customers in the drive replacement. Every attempt has been
made to ensure the accuracy of the information.

All installation and electrical work should be carried out by a
trained professional. ABB takes no responsibility for any
damages or other liability whatsoever (including any
consequential damages, even if ABB or an ABB representative
had advised of the possibility of such damages) resulting from
the use or selection of this document for any information,
apparatus, method, process, or similar item disclosed in this
guide. Specification is subject to change without notice.
This guide will help you to replace the ACH550 drive with the
ACH580 HVAC drive. Follow the steps outlined in this guide to
find the optimal replacement product and to expedite the
replacement process.
Step 1: Sizing of the drive and selecting options
Compare power range, mounting methods and dimensions to
select the appropriate ACH580 product compared to the
ACH550 drive, see the checklist items for some useful
guidance.
Step 2: Wiring and parameter setup
Compare electrical data and basic parameter range for optimal
replacement. Use the replacement ACH580 manual to assist
with the commissioning process.
Before beginning, some basic checklist items
All information regarding the control of your application
should be gathered from the ACH550 prior to selecting and
performing the actual replacement, control and parameter
settings should be noted to ensure consistency in the
replacement ACH580.
This checklist covers the main information you may require to
guide you through the replacement process. If the ACH550
cannot be powered, the technician should gather all the
information below that is not parameter related.
ACH550 upgrade basics
Record nominal power, current, voltage, etc. ratings taken
from your motor nameplate (to use in the ratings
comparison tables)
What type of signal is the speed/frequency command? e.g.
0-10VDC, 4-20 mA, via communications, or other?
Where is the speed/frequency command landed on the
drive?
What type of signal is the start/stop command? e.g. a relay
closure, via communications, or other?
Where is the start/stop command terminated on the drive?
Are there any other control or reference sources that
require additional IO options?
Are you using a door mounted control panel on an
enclosure door? If so, consider appropriate kit/method for
replacement keypad.
Are you using a door mounted control panel? Consider this
when choosing options
Consider the dimensions and mounting requirements,
cable sizes and heat losses
Review the control terminal wiring and ensure the cable
lengths are sufficient
Is the Building Automation System communicating with the
drive over a communication protocol? e.g. BACnet. If so,
document the appropriate communication settings, such
as MAC ID, Device Object Instance ID, Baud, etc.
Are there any analog outputs from the drive that are wired
to another device? If so, document the type of signal (e.g
4-20 mA), where it was terminated on the drive, what it was
used for, and any scaling of the signal.
Are there any relay outputs from the drive that are wired to
another device? If so, document where it was landed on the
drive and what it was used for.
Are there any other control or reference sources that
require additional IO options?