The MVI56 IEC 60870-5-104 Server Communication Module allows
ControlLogix compatible processors to interface easily with IEC 60870-5
104 protocol-compatible hosts.
The MVI56-104S module acts as an input/output module between the IEC
60870-5-104 Ethernet network and the ControlLogix processor. Data
transfer between the module and the processor is asynchronous from the
actions on the network. Databases are defined by the user for the module to
hold data as required by the protocol.

General Specifications
Single Slot - 1756 backplane-compatible
The module is recognized as an Input/Output module and has access to
processor memory for data transfer between processor and module.
Ladder Logic is used for data transfer between module and processor.
Sample ladder file included.
Configuration data obtained from configuration text file downloaded to module.
Sample configuration file included
Local or remote rack
General Specifications - 104S
Operating in server mode (only), the 104S protocol implementation accepts commands
from an IEC-60870-5-104 Client to read data stored in or write data into the gateway’s
internal database memory registers. The 104S implementation is also capable of generating
unsolicited messages. Unsolicited messages can be either spontaneous (event-driven) or
cyclic (timing-driven) communication.
The remote Client device uses the fully-configurable gateway memory database to control
outputs and monitor inputs to devices on the
IEC 104 network. Changes to the gateway database can also be used to transfer monitoring
and control data to devices connected to
the gateway using another installed network protocol. The 104S gateway thus provides a data
transfer solution between an IEC 60870
5-104 Ethernet network and other serial and Ethernet network protocols, as well as proprietary interfaces.
General specifications include:
User-definable database memory usage, based on data types and point counts
Protocol implementation conforms to the IEC 60870-5-104 specification with fully-configurable
parameters
SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions (events)
IEC 60870-5-104 Server Specifications
Operating in the Server mode, the module accepts commands from a Client(s) to
read/write data stored in the module’s internal registers. This data is easily and
continuously transferred between the MVI56-104S, Edition 2 module and the
ControlLogix processor’s data registers.
The IEC 60870-5-104 Server functionality supported by the module includes:
The IEC 60870-5-104 communication driver is built in accordance to the approved
IEC specification
The module functions as a Server on the network supporting data read/write
commands from an IEC 60870-5-104 client on the network
One TCP server socket
Supports unsolicited messages, either cyclic or spontaneous (cyclic rate is
configurable)
Supports clock synchronization commands from client or from the ControlLogix
processor
Supports Group interrogation (Global, General 1 to 16, Global Counters, Counters
1 to 4)
Event timestamping configurable by type (None, 24 bit, 56 bit)
Event queue supports 99 points for each data type
Optional user defined list of acceptable client host IP addresses
Configurable Common ASDU address (sector) and Information Object Address
An IEC Interoperability Document for the MVI56 is available which fully documents
data types supported by the module