SILworX allows you to program and configure your HIMA safety-related controllers
and diagnose errors in an intuitive user interface. This results in fewer user errors
and faster engineering – enabling you to commission your safety system more quickly
and adapt it to new requirements immediately.
The engineering tool is a part of the HIMA Smart Safety Platform and adapts modularly
to your project requirements. In addition to its core function, SILworX also offers Industry
4.0 functions for user-specific programming. Benefit from efficient and flexible engineering
solutions for future-proof digitalization of functional safety with added value.

SILworX offers a modular approach. In addition to its core functions, the programming of
safety controllers, it also offers industry 4.0 features that can be deployed flexibly to meet
the application´s specific requirements. All of these features are safety certified.
Thanks to the new interface external plug-ins such as scripts, programs or functions can
also be integrated into your own automation project.
HIMax adapts to all I/O-count, response-time and fault-tolerance requirements as well
as centralized and distributed applications. HIMax delivers availability for life by enabling
uninterrupted system operation throughout your plant’s life cycle. Hardware and software
changes can be performed without system interruption. Alternative CPU modules make
HIMax suitable for meeting high performance and critical control requirements as well
as for use in small and mid-sized safety applications.
Highlights
• XMR architecture and integrated redundancy management deliver “availability for life”
• Unique common-cause protection
• All changes, additions and maintenance procedures are possible without stopping
a HIMax system
• CPU self-educates when processor module is replaced
• Proof tests can be conducted online
• Stores up to 2.500 diagnostic entries in the processor module and 500 entries per
I/O module automatically
• Multitasking – run up to 32 user programs simultaneously
• Sequence of event (SOE), storage for 5.000 events, 1 ms resolution quality
• Redundant integrated and protected power distribution
• Two or three wiring inputs/outputs per channel to help eliminate additional wiring
• Remote rack functionality enables star topology
• HIMax – HIMatrix PES, redundant link via SafeEthernet
• Optimize process simulation and operator training with the HIMax Safety Simulator X-OTS
ABB AC 800M Processor Unit 3BSE018105R1
ABB DCR 500 Servo Drive ADPI-01/DCR501B0000-00-21P0050-X000N0V00
ABB ACS250-03U-18A0-4+B063 AC DRIVE
ABB DSQC639 3HAC 025097-001/14A Computer Controller Unit
Alstom Controller SIR4 85kv/1200 V0701624-201101 Untested (clean)
Alstom Alspa Breakout Fuse Board 1SNL491237R0100 Plat Surville Fusible AIT016
Alstom Signaling Wayside Product Type B Series Relay
Alstom Signaling 30800-007-01 Receiver Assembly. Train Rail Transit
ABB Alstom HTGR102976R0001 Spring Loaded Over Pressure Safety Check Valve
CONVERTEAM 70SI01 / 70SI01
CONVERTEAM 3D8FP1012A / 3D8FP1012A
ALSTOM POWER MVS3000-4011 DRIVE DATAMANAGER KEYPAD 20X4310/10B 2333321
ALSTOM Signaling Wayside Product Automation Type-B DC-Relay A62-125 56001-922-07
Alstom Low Burden Tripping Relay MVAJ11L1GB0771A
Alstom Converteam ALSPA MD2000 54-400 Frequency Converter