Retransmit
The FBT-6 checks for any device not responding to a LAS pass token
and indicates the address (decimal and hexadecimal) of the last device
that failed to respond to the LAS pass token, together with the number
of missed pass tokens since the function was reset. If more than 250
re-transmissions are detected, the display will read “250+”. Pressing
and holding the “SELECT” key for 2 seconds will reset the re-transmit
count for all devices to zero. Pressing the “SELECT” button for less
than 2 seconds displays the number of detected, missed pass tokens
for each device.

Add–Drop
If a new device is added to the network, the Monitor will display
its address and signal level. If a device does not respond to a Pass
Token frame, the device is considered “dropped” by the FBT-6 and
the Monitor will display the address and last known signal level of the
dropped device.
Shield Short
If a short circuit between the + fieldbus wire and the cable shield
is detected, “(+) TO SHIELD SHORT” is displayed. If the short
is between the – wire and the shield, “(–) TO SHIELD SHORT” is
displayed. If a detected shield short goes away the Monitor indicates
an INTERMITTENT SHIELD SHORT to (+) or (-).
Save Report
Saves the data collected by the Monitor as a report. Up to 8 reports
may be saved from multiple segments and/or multiple locations on
one segment.
Transfer Report
Connect the Monitor to a PC USB port and transfer the saved reports
to Excel files on the PC.
Set Report Names
Customize the names of the reports saved in the Monitor to easily
identify the report source
Set OK/BAD Limits
Change the limits at which Monitor measurements transition from OK
to BAD to establish customized plant standards.