When redundant power supplies are running, current sharing circuitry balances the load to reduce heat
and improve the reliability of the power supplies.
In the event that on supply needs to be replaced, the recommended method for changing
Power Modules is with the power off (to the module being removed and the module being inserted).
The system will tolerate this “cold swap” method without failure.
Each main power supply has four LEDs to indicate power supply health (OK, Input Fault,
Overtemperature, and Power Supply Fault).
See MicroNet Plus Power Supply Troubleshooting (Section 5.5) for a description of the LED indications.
Input power connections are made to the power supply through a plug/header assembly on the front of
the power supply.

The MicroNet Plus Expansion Chassis may use either single or redundant power supplies.
Each power supply module produces three regulated outputs:
24 V @ 12 A (max), 5 V @ 32 A (max, derated above
55 degree C external ambient temperature), and 5 V Precharge @ 3 A (max).
A motherboard located on the back of the chassis provides the
interconnection of the three outputs from each power supply module
into three corresponding power busses: 24 V bus, 5 V bus, and 5 V precharge bus.
The 24 V and 5 V busses are load shared between the two power supply modules.
The 5 V precharge bus is not load shared.
Power output regulation at the motherboard, including line, load, and temperature effects,
is less than ±10% for the 24 V bus, +/-5% for the 5 V bus,
and +/-10% for the 5 V Precharge bus.
The 5 V and 5 V Precharge busses are not for external use.
The 24 V bus is accessible from the motherboard for
external use (protected by 5 A fuses on the source and return lines).
| Woodward 8440-2165 SPM-D2 Synchronizers |
| Woodward 8440-1945 easYgen-3400/3500/P1/P2 |
| Woodward V45RD-1515-FUEXM-X-S-X 9907-1431 ACTUATOR w/REMOTE SERVO |
| Woodward 8440-2047 easYgen-3400/3500, LS5 & RP-3000 MARINE Packages |
| Woodward 9907-838 LSM Load Sharing Module |
| Woodward 8440-2046 easYgen-3400/3500, LS5 & RP-3000 MARINE Packages |
| Woodward 8440-2052 easYgen-3100/3200 |
| Woodward V45TV-2515-MURXM-X-S-X 9907-2085 Industrial Turbine Actuator |
| Woodward V45RD-1505-FUEXM-X-S-X 9907-1486 ACTUATOR w/REMOTE SERVO |
| Woodward 8444-1111 MFR300 kW Transducers with Protection |
| Woodward 8440-2057 easYgen-3100/3200 |
| Woodward 8444-1108 MFR300 kW Transducers with Protection |
| Woodward V45RD-1515-FURXM-X-S-X 9907-1432 ACTUATOR w/REMOTE SERVO |
| Woodward 8441-1160 easYprotec-100 |
| Woodward 8440-2049 easYgen-3100/3200 |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved