The DeviceNet Router/B provides a powerful and easy to configure solution to exchange data between
DeviceNet™ and EtherNet/IP™, Modbus TCP/IP or Modbus RTU networks. The module can be
configured as a DeviceNet Scanner or a DeviceNet Device - allowing the user to not only integrate
DeviceNet devices into a Logix or Modbus system, it also allows EtherNet/IP or Modbus devices in an
existing DeviceNet network.

As a DeviceNet Scanner, the module can connect to over 63 DeviceNet devices where the cyclic
input/output data from each device can be mapped to an EtherNet/IP Target/Originator or a Modbus
Server/Client. The module can be configured to exchange explicit messages with DeviceNet nodes.
As a DeviceNet Device, the module supports input/output data sizes of up to 256 bytes using polled or
change-of-state connections.
In PCCC Client mode, the module can asynchronously exchange data between a DeviceNet Scanner
and an Ethernet PCCC device.
As an EtherNet/IP Target, the module supports the following method to read/write data from an
EtherNet/IP network.
• With support for EtherNet/IP Class 1 connection, DeviceNet data can be mapped to an input
and output Class 1 cyclic connection to the Logix controller.
As a EtherNet/IP Originator, the module supports three methods to read/write data from an
EtherNet/IP network:
• With support for EtherNet/IP Explicit messaging, the router can use Class 3 or unconnected
messages (UCMM) to send/receive data from remote EtherNet/IP devices.
• With support for Direct-To-Tag technology, DeviceNet data can be read from or written to
Logix tags without the need for code in the Logix controllers.
• With support for EtherNet/IP Class 1 connection, the router can own up to a maximum of 10
EtherNet/IP devices and exchange DeviceNet data using the device’s input/output
assemblies.
As a Modbus Server, DeviceNet data can be written to the module’s internal Modbus registers. These
registers can be accessed by a remote Modbus client using the Modbus TCP/IP or RTU protocol.
As a Modbus Client, DeviceNet data can be written to the module’s internal Modbus registers. The
integrated Modbus auxiliary mapping feature can be used to configure Modbus data exchange between
multiple Modbus server devices and the module’s internal Modbus registers using the Modbus TCP/IP
or RTU protocol.
The DeviceNet Router B is configured using the Slate Configuration Utility software tool.
The DeviceNet Router B includes a webserver to display DeviceNet operation and communication
statistics and advanced diagnostics functions like built-in packet capture for the various protocols. The
router has two Ethernet ports to support Device-Level-Ring (DLR) architectures.
Features
• DeviceNet Scanner or DeviceNet Device
• Support for multiple DeviceNet network baud rates (125K, 250K, 500K)
• Support for DeviceNet pass-through or explicit messaging
• PCCC client mode to connect to Ethernet-only PanelViews to an existing DeviceNet network
• EtherNet/IP Target or Originator with support for Class 1 connections
• Supports Modbus TCP/IP (Ethernet) and Modbus RTU (Serial) Client/Server
• Direct-to-Tag Technology
• Dual Ethernet ports with support for DLR (Device Level Ring)
• Support for NTP (Network Time Protocol) for external clock synchronization
• Advanced Diagnostics, including packet capture
Configuration
The Slate Configuration Utility software is used for configuration and troubleshooting of the module. The stand-alone
configuration utility allows users to define the setup and configuration of the DeviceNet Router module, connections
with controllers and devices.