Power Engineering 
K-JIANG
NameDescriptionContent
Current Location:

Prosoft PLX51-PBS PROFIBUS DP Slave to EtherNet/IP™, Modbus® TCP/IP, or Modbus® Serial Gateway

From:ProSoft | author:Mr.Chen | Time :2026-04-17 | 9 view: | 🔊 Click to read aloud ❚❚ | Share:

Modbus® Serial networks for PROFIBUS DP networks by operating as a PROFIBUS

DP slave.

For easy integration to a Rockwell Automation Controller, the gateway and

configuration software create dynamic AOI’s based on the user configuration to add

logical tag names to the PLC project file. Thus, reducing programming time.

For configuration of Modbus TCP/IP or Modbus Serial Networks, the module will

automatically map PROFIBUS DP data points to registers on a Modbus network.

With advanced tools such as a built in PROFIBUS DP packet capture utility,

PROFIBUS DP network commissioning time can be greatly reduced.

Dual Ethernet ports of the module can support either DLR (Device Level Ring)

topology, or can be used as an embedded switch for flexible installation options.

With support for up to 1536 bytes of Input and Output data, and up to 4 EtherNet/IP

connections back to the processor, this module provides performance and data

throughput for even the most demanding of PROFIBUS applications.

As a PROFIBUS DP slave device, the module can emulate from 1 to as many as 10

slave DP nodes, providing up to 1536 bytes of Input and Output Cyclic I/O data

between EtherNet/IP devices and a PROFIBUS DP master. This eliminates the need

for using DPV1 messaging when more than 244 bytes of data needs to be exchanged

between a PROFIBUS master and an EtherNet/IP network.

Features

 Supports DLR for EtherNet/IP networks

 Support for either EtherNet/IP, Modbus TCP/IP, or Modbus Serial Communication networks

 PROFIBUS slave OR multi-slave support

 PROFIBUS packet capture tool built in

Configuration

The PLX50 Configuration Utility software is used for configuration and troubleshooting of

the module. The stand-alone configuration utility allows users to define the setup and

configuration of the PROFIBUS DP module, connections with Rockwell Automation controllers

and devices over EtherNet/IP, and build custom Add-On Instructions (AOIs) to be imported

into Studio 5000 applications.

With the ability to import custom AOI’s into the Studio 5000 environment and advanced

PROFIBUS DP tools such as the packet capture utility, commissioning time of a network

can be greatly reduced.

EtherNet/IP™ Server (Class 1 Adapter)

As an EtherNet/IP server, the gateway operates as an Adapter with up to 4 Class 1 I/O

connections to a Controller (Scanner) on an EtherNet/IP network. The use of

EtherNet/IP Class 1 I/O connections for transfer of PROFIBUS DP cyclic data, provides

fast data transfer between networks for increased performance on time critical

PROFIBUS DP applications.

EtherNet/IP Client

As an EtherNet/IP client, the module can generate Get Attribute, Set Attribute, Set

Static, or Custom messages using either Class 3 messaging or UCCM messaging on

EtherNet/IP. With support for up to 5 unique devices on one module and a total of up to

50 mapping functions, this functionality allows EtherNet/IP devices such as Overload

Protection Relays and Variable Frequency Drives to be mapped onto a PROFIBUS DP

network.

Modbus TCP/IP

On a Modbus TCP/IP network, the module will operate as either a Modbus TCP/IP

Client or Server device.

As a Modbus TCP/IP client the module can be configured to automatically read/write all

PROFIBUS DP data with a slave device for easy setup and configuration, or the

Modbus Auxiliary Map feature will allow you to configure data transfer to customize the

mapping to meet specific application requirements.

As a Modbus TCP/IP Server all information from the PROFIBUS DP network is stored in

continuous registers in the module for easy configuration and efficient mapping of data

to a Modbus TCP/IP client.

Modbus Serial

On a Modbus Serial network the module will operate as either a Master or a Slave

device supporting either RS232 or RS485 communication networks.

As a Modbus Serial Master the module can be configured to automatically read/write all

PROFIBUS DP data with a slave device for easy setup and configuration, or the

Modbus Auxiliary Map feature will allow you to configure data transfer to customize the

mapping to meet specific application requirements.

As a Modbus Serial Slave all information from the PROFIBUS DP network is stored in

  • Prosoft PLX51-PBS PROFIBUS DP Slave to EtherNet/IP™, Modbus® TCP/IP, or Modbus® Serial Gateway
  • Prosoft PLX51-PBM PROFIBUS DP Master/Slave to EtherNet/IP™, Modbus TCP/IP®, or Modbus® Serial Gateway
  • Prosoft PLX51-DLplus-232 Data Logger Plus
  • Prosoft A-CNR ControlNet Router
  • Prosoft A-TSM/B Time Sync Module
  • Prosoft A-XGPS XPosition Module
  • Prosoft PLX32-EIP-104 EtherNet/IP to IEC 60870-5-104 Gateway
  • Prosoft PLX32-MBTCP-104 Modbus TCP/IP to IEC 60870-5-104 Gateway
  • Prosoft A-PAL/B PA Link Series B PA Gateway
  • Prosoft A-DNTR/B DeviceNet Router Series B
  • Prosoft A-DH485R/B DH485 Router
  • Prosoft PLX51-DNPS Distributed Network Protocol (DNP3) Gateway
  • Prosoft PS-QS-2x10-F Universal QuickServer Gateway
  • Prosoft PLX51-DNPM Distributed Network Protocol (DNP3) Master Gateway
  • Prosoft A-CANOR/B CANopen Router/B
  • Prosoft PS-QS-3x10-F Universal QuickServer Gateway Dual Ethernet Port
  • Prosoft EtherNet/IP™ to Remote I/O or DH+ Gateway AN-X4-AB-DHRIO
  • Prosoft A-J1939R/B J1939 Router/B
  • Prosoft PS-QS-1x11-F LonWorks QuickServer Gateways
  • Prosoft AN-X3-GENI EtherNet/IP™ to GE Genius™ I/O Gateway
  • Prosoft A-FFL/B FOUNDATION™ Fieldbus H1 Master for EtherNet/IP™ and Modbus® TCP
  • Prosoft ELX3 Industrial Edge Gateway
  • Prosoft A-CFR ControlNet Fiber Repeater
  • Prosoft A-CANBR/B CAN Bus Router/B
  • Prosoft EtherNet/IP™ to Reliance AutoMax DCS or Remote I/O Gateway, non-CE AN-X-AMX
  • Meggitt C327845-11 Valve, 2″ Isolation Valve (24VCD) ATEX certified
  • Woodward 8440-1706 Synchronizer Module | SPM-D11 Generator Control
  • WOODWARD 8440-2052 H Digital speed controller
  • Woodward PEAK200-HVAC 8200-1501 digital steam turbine controller
  • Woodward EASYGEN-3200-5 8440-1992 A Genset Control
  • Woodward 8440-2052 EasyGen 3200-5-P2 Genset Controller
  • 8237-1246 with 5437-1119 Woodward ProTech-GII Overspeed Protection Device
  • WOODWARD synchronization module SPM-D11 8440-1703
  • 8237-1369 with 5437-1119 Woodward ProTech-GII Overspeed Protection Device
  • 8237-1660 with 5437-1124 Woodward ProTech-GII Overspeed Protection Device
  • Woodward BUM60-1224-54-B-001-VC-A0-0093-0013-G003-0000 3522-1004
  • Woodward 8901-457 PLC Module Brand
  • 5448-890 WOODWARD SPM-D10 series synchronizer
  • Woodward 5437-1067A Actuator Control Module
  • Woodward 8440-1666 B Load Share Synchronizer Module
  • Woodward 8440-1706 A SPM-D11 Load Share Synchronizer
  • Woodward 5466-425 - Analog I/O Module
  • Woodward 5466-318 Kernel Power Supply Module
  • Woodward 5453-203 Operator Interface Panel
  • Woodward 9907-1106 pressure regulating valve controller
  • Woodward ProTech-GII 8237-1600 Panel Mount
  • GUTOR 0P6257 Industrial-Grade Power Component
  • Zygo 8010-0105-02 ZMI-501 Channel Isolation Board
  • ZYGO CS1115-801-346 Laser Head Cable
  • ZYGO HSSDC2 TO HSSDC2 CABLE 1115-800-055 Fiber Channel Cable
  • ZYGO HSSDC TO HSSDC2 CABLE 1115-800-056 Fiber Channel Cable
  • ZMI-4104C Zygo Ultra high precision measurement module
  • Zygo ZMI-2002 8020-0211 Dual Axis 6U VME Measurement Board
  • ZYGO 7702 8070-0102-35 Laser Interferometer Measurement Head
  • ZYGO 7702 8070-0102-01X Laser Interferometer Measurement Head
  • Zygo ZMI-4004 4-Axis VME64x Measurement Board
  • Zygo 1115-801-346 laser head cable
  • ZYGO 8010-0105-01 Power Supply
  • Zygo ZMI-2002 Dual Axis 6U VME Measurement Board
  • Zygo ZMI-2002 8020-0211-1-J Dual Axis 6U VME Measurement Board
  • ZYGO 8070-0902-01X Laser Head
  • Yokogawa AIP830-001 AIP830 Operation Keyboard
  • GE MVAJ103RA0802A MIDOS HIGH/LOW BURDEN TRIP RELAY W/ HAND RESET 8NO+2NC 110V
  • GE MVAJ104RA0804A MIDOS TRIPPING RELAY ELEC RESET 8MAKE 2BREAK CONT 110/125V
  • GE MVAJ23R1AB0505F MIDOS HIGH BURDEN TRIP RELAY
  • MVAJ Relay MVAJ103JA0804A AREVA ALSTOM 767002M
  • PIONEER MAGNETICS PM36218B-10P-1-8PH-J POWER SUPPLY
  • MVAJ055RA0802B | GE Grid Solutions | Trip Relay Module
  • PM3328B-6-1-3-E 80026-524-01 PIONEER MAGNETICS Module
  • Pioneer Magnetics PM3328B-6-1-3-E POWER SUPPLY
  • Pioneer Magnetics PM3326B-6-1-2-E 80026-529-01 POWER SUPPLY
  • Pioneer Magnetics PM3398B-6P-1-3P-E 80026-172-23 POWER SUPPLY
  • Pioneer Magnetics HYRSP-1500-56 High-Precision Relay Module
  • Pioneer Magnetics PM3398B-6-1-3-E 80026-172-24 POWER SUPPLY
  • Pioneer Magnetics PM3398B-6-1-3-E POWER SUPPLY
  • Pioneer Magnetics PM3328BP-6 POWER SUPPLY
  • Pioneer Magnetics PM3398BP-6-1-3-E POWER SUPPLY
  • Pioneer Magnetics PM1253AL-6-3-Z03 Magnetic Device
  • Pioneer Magnetics 80026-529-01 PM3326B-6-1-2-E POWER SUPPLY
  • Pioneer Magnetics PM3398B-6-1-3-E 80026-121-01 POWER SUPPLY
  • Pioneer Magnetics PM33211BP-5-1-3-F | Power Supply
  • KUKA RDW2 2000 Series Robot Circuit Board
  • KUKA DSE-IBS 3.02 Industrial Automation Module
  • 1FK6081-6AF71-1ZZ9-Z KUKA SERVO MOTOR
  • Prosoft PLX31-EIP-MBS EtherNet/IP™ to Modbus® Serial Communication Gateway
  • Prosoft PLX31-EIP-MBS4 EtherNet/IP to Modbus Serial 4 Port
  • Prosoft AN-X-TI EtherNet/IP to Texas Instruments Remote I/O Master Gateway, non-CE
  • Prosoft MVI69L-MBTCP Modbus TCP/IP Lite Communication Module
  • Prosoft MVI69E-LDM Linux Development Module for CompactLogix™
  • Prosoft ILX69-PBS PROFIBUS DPV1 Slave for CompactLogix
  • Prosoft ILX69-PBM PROFIBUS DPV1 Master for CompactLogix
  • Prosoft MVI69E-AFC Enhanced Liquid & Gas Flow Computer for CompactLogix®
  • Prosoft MVI69E-GEC Generic ASCII Ethernet Communication Module
  • Prosoft MVI69E-GSC Generic ASCII Serial Communication Module
  • SCANLAB INTELLISCANDE III14-532NM laser scanning module
  • SST 5136-PFB-PCI Profibus Interface Card
  • SST SST-DN3-PCI-2 DSQC658 DeviceNet Communication Interface Board
  • SST SST-PFB-CLX Profibus Interface Card
  • SST 5136-DN-PC DeviceNet Interface Card
  • SST 5136-RE-VME ControlNet Redundant Card
  • SST 5136-DNP-CPCI Compact PCI Interface Card
  • SST 5136-DNP-PCI Profibus Interface Card
  • SST 5136-PFB Profibus Interface Card
  • Scanlab intelliWELD II FT (with F-Theta objective)
  • Scanlab intelliWELD II PR (with prefocus optic)
  • ABB 3BSE020828R1 DSAI 130DK01 Analog Input Board with
  • TRICONEX AI3351S2 Analog Input Module
  • TRICONEX DO 3626X Digital Output Module
  • Triconex CM3201 S2 Communication Module
  • TRICONEX 8305A Tricon Safety System Expansion/RXM Rack Power Supply
  • TRICONEX 9771-210 7760059032 Safety Redundant Controller
  • Triconex 9668-110 7400172-110 Termination Board
  • Triconex MP3101 Trident Redundant Processor Module
  • Triconex IMFF4703x | Fault-Tolerant Fieldbus Module
  • Triconex 4200 RXM Remote Extender Module
  • Triconex 4200 RXM Remote Extender Module
  • TRICONEX 3503EC1 Digital Input Module
  • Triconex 4000103-546 Communication Module
  • 4000094-350 | TRICONEX | Communication Module
  • TRICONEX 4000093-346 Three-Module Redundancy
  • TRICONEX 3902X Universal Input/Output module
  • TRICONEX 9760-2 7300150-001 Safety Instrumented System (SIS) Module
  • TRICONEX PLM3900N | Process Logic Module
  • TRICONEX 9771-210F Digital Input Module
  • TRICONEX MP3009 SIL-3 certified safety controller
  • Bachmann PPC1215WM/BE1/AM72/4G/P/LX Panel PC
  • Bachmann PPC1212WM/BE1/AM72/4G/P/LX Panel PC
  • Bachmann PPC1210WM/BE1/AM72/4G/P/LX Panel PC