Key Features
• Outstanding drilling rates are made possible by significantly
reduced step response times
• New motor design with improved thermal management
• Lightweight beryllium mirrors
• Digital dynAXISse
encoder technology
• Automatic jump delay setting for all jump lengths (1)

Typical Applications
• PCB industry
• Via hole drilling
• High density interconnects (HDI)
Specifications
Aperture 20 mm
Maximum scan angle(2) ± 0.349 rad
Wavelength(3) 9400 nm
Step response
(positioning and settling to ±5 μm at
100 mm focal length)
0.13 ms at 0.2 mm
0.22 ms at 0.5 mm
0.29 ms at 1 mm
Temperature drift(2) Offset: < 10 μrad / K
Gain: < 5 ppm / K
Long-term drift(2)
(8-hour-Drift after 30 min warm-up,
at constant ambient temperature and load)
Offset: < 50 μrad
Gain: < 50 ppm
Power supply requirements 48 V, 3 A (RMS)
Water cooling requirements 3 l / min at 20 °C and
Δp < 1 bar, p < 4 bar
(1) RTC6 control board required
(2) all angles are optical angles
(3) others on request