The A-CNR ControlNet Router provides an efficient method of bridging between
ControlNet and Ethernet networks. The module provides intelligent routing between
EtherNet/IP™ or Modbus TCP/IP® and a ControlNet network. The module can be
configured as a ControlNet Target or an Originator. As a ControlNet target, a Logix
controller can own the ControlNet router using a scheduled connection. As a ControlNet
originator, the module can be configured to own ControlNet I/O or exchange data with up
to 10 ControlNet devices.

The router can also be configured as a PCCC Client (allows the module to emulate a
PLC5 or SLC5 providing legacy interface to PanelViews), EtherNet/IP target or originator,
and as Modbus TCP/IP client or server.
As an EtherNet/IP target, a Logix controller can own the router using a Class 1
connection. As an EtherNet/IP originator, the router supports class 1 connection or
explicit messaging.
As a Modbus TCP/IP client, the router can map ControlNet data to Modbus registers for
exchange with Modbus TCP/IP servers. As a Modbus TCP/IP server, the router can
exchange the ControlNet data with Modbus TCP/IP clients.
The I/O data can be accessed via Ethernet using either the PCCC or EtherNet/IP or
Modbus TCP/IP protocols. The support for PCCC protocol allows the router to emulate
user-defined PLC5-type data files data simplifying the migration to Ethernet-only
PanelViews. The router also provides a range of statistics on Ethernet and ControlNet to
assist with fault finding.
A built-in webserver provides detailed diagnostics of system configuration and operation,
including the display of ControlNet operation and communication statistics, without the
need for any additional software.
Features
Own ControlNet I/O enabling the migration from legacy Logix systems/controllers to
newer EtherNet/IP Logix platforms, without replacing the existing ControlNet I/O.
Can be configured as a ControlNet Target or Originator.
Can operate as ControlNet Keeper.
Supports Promiscuous Capture mode allowing the ControlNet Router to capture all traffic
on the ControlNet network.
Can be configured as an EtherNet/IP Target or Originator.
Can be configured as a Modbus TCP/IP Client to exchange ControlNet data with Modbus
TCP/IP servers.
Can be configured as Modbus TCP/IP Server to exchange ControlNet data with Modbus
TCP/IP clients.
Connect Ethernet-only PanelViews to Logix via ControlNet.
Supports Scheduled & Unscheduled ControlNet for PanelViews.
Program Logix controllers via ControlNet.
Supports Redundant ControlNet and Ethernet.
Advanced Diagnostics, including packet capture and webserver.