The field network is wired in a ring configuration from Port A around a loop to Port B of the
network master. Beginning at Port A, the network is wired to Port A of the first actuator and
then from Port B of the first actuator to Port A of the second actuator and so on until the
network returns from Port B of the last actuator to Port B of the network master. Networks
may have parallel wired (bus wired) actuators between series wired actuators. Always wire
parallel actuators to Port A and remove termination and bias.
Do not connect more than 15actuators in parallel between any two series connected actuators.
Networks are polarized with (+) and (-) symbols on all drawings.

Proper operation requires that polarity be observed at all connections.
Connect the field networks to the Port A and B connectors on the NIM in the
network master as shown in Figure 9. The networks must be connected to Port A and Port B
of the valve actuators as shown in the wiring diagram of the XTE3000/ICON3000 IOM. Others
320B and RTS, please refer to their IOM for network wiring diagram. Controlinc 320B Quick
Start manual. Controlinc supports many different network topologies. This manual supports
only a single ring E>Net network topology that allows a combination of parallel (bus) and series
E>Net connections on the same network.
Network Master Mounting
If the system is supplied from the factory in an NEMA enclosure, no internal wiring
is required except for connecting power and field network wiring. The next three
sections (Sections 2.1. 2.2 and 2.3) discuss mounting, power input and field network
wire connections to the NIM.
PAC Machine Edition programming software provides a universal engineering development
environment for all programming, configuration and diagnostics of PACSystems. A PACSystems CPU is
programmed and configured using the programming software to perform process and discrete
automation for various applications. The CPU communicates with IO and smart option modules
through a rack-mounted backplane. It communicates with the programmer andor HMI devices via
the Ethernet ports or via the serial ports COM1 and COM2 using Serial IO, or Modbus RTU slave
protocols.
WOODHEAD INDUSTRIES 60998-18 / 6099818
WOODHEAD MINI 2 PIN MALE RECEPTACLE CORD-SETS 40707
Woodhead 1200720178 Micro Change Cord Set
Woodhead 5AA73 1200651072 Micro-Change 4P Female Cord Set
DANIEL WOODHEAD 81230-007 883032D01M005 CORDSET
Schenck Process VSE20100 Disocont Module w/Mount VLW20150.01 Software
Schenck VET010V Ethernet Module Board w/ Mounting Hardware NWB
Schenck Vibroport 30 - Portable Vibration Analyzers & Field Balancer - PF86
SCHENCK 5AP920.1505-K1 1 OPERATOR INTERFACE PANEL
SCHENCK DNG-100 DNG100 RACK ID61300 UP TO 24 MONTHS WARRANTY
SCHENCK VC-1000-CV110 / VC1000CV110
SCHENCK VNT0450 V054017.B01 & Test with warranty
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2026 Cld , All Rights Reserved K-JIANG All rights reserved