1. INTRODUCTION
This manual provides instructions and procedures necessary
to install, operate and troubleshoot the Moog Inc. Series 79-100 Industrial
Servovalve. Loop closure of the third stage spool requires external electronics
consult factory for suggested Moog electronics model numbers.
2. OPERATION
The Moog Inc. Series 79-100 Industrial Servovalve consists of a two stage
mechanical feedback pilot valve and a high flow third stage with electrical
feedback. Proper operation requires the use of user provided electronics to
condition the spool position transducer, compare actual spool position to
command and to generate a current signal to the pilot valve.

In a typical system, a spool position command signal is compared to the
actual spool position signal in the servoamplifier.The error (difference) is
converted to a current signal and used to drive the pilot valve spool in the
proper direction.The pilot valve spool directs oil flow to one end of the third
stage spool, moving the spool. Spool movement is sensed by the spool position
transducer and spool motion continues until the spool position signal is equal
to the command signal.At this point, the servoamplifier current returns to near
zero, the pilot valve returns to null and the third stage spool is held in position.
3.HYDRAULIC SYSTEM PREPARATION
To prolong servovalve operational life and to reduce hydraulic system
maintenance,it is recommended that the hydraulic fluid be kept at a cleanliness
level of ISO DIS 4406 Code 16/13 maximum,14/11 recommended.The most
effective filtration scheme incorporates the use of a kidney loop or “off-line”
filtration as one of the major filtration components.The filter for the “off-line”
filtration scheme should be a ß3≥75 filter for maximum effectiveness.
Upon system startup and prior to mounting the servovalve,the entire
hydraulic system should be purged of built-in contaminating particles by an
adequate flushing.The servovalve should be replaced by a flushing manifold,and
the hydraulic circuit powered up under conditions of fluid temperature and fluid
velocity reasonably simulating normal operating conditions.New system filters
are installed during the flushing process whenever the pressure drop across the
filter element becomes excessive.The flushing processes should turn over the
fluid in the reservoir between fifty to one hundred times.
To maintain a clean hydraulic system,the filters must be replaced on a
periodic basis. It is best to monitor the pressure drop across the filter assembly
and replace the filter element when the pressure drop becomes excessive. In
addition to other filters that are installed in the hydraulic circuit,it is
recommended that a large capacity,low pressure ß3≥75 filter be installed in the
return line.This filter will increase the interval between filter element
replacements and greatly reduce the system contamination level.
4.INSTALLATION
The Moog 79-100 Series Industrial Servovalve may be mounted in any
position,provided the servovalve pressure,control and return ports match
respective manifold ports.
Caution: If the servovalve is mounted vertically,the third stage spool may drift
to one side when hydraulics are shut off.This may result in sudden movement of
equipment when starting up.
The mounting pattern and port location of the servovalve is shown on
Figure 2.The servovalve should be mounted with 3/8-16 x 2.25 inch long high
strength socket head capscrews.Apply a light film of oil to the screw threads
and torque to 50 foot pounds.
On selected models,the pilot valve supply and return may be supplied
through external lines attached to the valve body or an intermediate manifold.
Wire mating connector for desired coil configuration and polarity.Thread
connector to valve.Wire transducer according to the installation drawing,
Figure 2.
5.MECHANICAL NULL ADJUSTMENT
There is no mechanical null adjust.Typically,a bias potentiometer is
provided on the electronics to null the valve.If adjustment of the transducer is
required,refer to the proper steps below.
a. Remove the two socket head screws holding the transducer cover to the
end cap.Carefully remove cover to prevent damage to the transducer
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com