The ELX3158 analog EtherCAT input terminal allows the direct connection
of intrinsically safe field devices located in hazardous areas classified zone
0/20 or 1/21. It supplies measuring transducers located in the field and
transmits their analog measuring signals electrically isolated to the
automation device. With a technical measuring range of ±107% of the
nominal range, the terminal also supports commissioning with sensor
values in the limit range and evaluation according to NAMUR NE43.

The error LEDs indicate an overload condition and wire breakage.
EtherCAT terminals of the ELX series must always be operated in
conjunction with the ELX9560 power supply terminal. This terminal
generates an electrically isolated output voltage (24 V EX) from the
input voltage (24 V DC) for supplying the subsequent ELX terminals.
If a new power supply is required, the combination of an ELX9410 and
an ELX9560 can be used so that further ELX terminals can be added.
The ELX terminal segment must be terminated with one ELX9012. two
ELX9410 or one EK1110. The use of two ELX9410 allows the use of EL
terminals behind ELX terminals. With the EK1110. the terminal segment
can be continued via an EtherCAT cable, for example to implement cable
redundancy.