The XAMP preamplifier is approved for use with
all wetted T5. and T17 transducers, to be used in
conjunction with the XGF868i or the GF868. A complete
potted assembly, the XAMP is a great improvement
in overall system reliability, simplicity and cost as
compared to previous preamplifiers.

The XAMP is mounted directly on the end of the
transducer. All cable connections are made in the
junction box. These is no need for an external junction
box and cable.
The XAMP package must be ordered as a separate line
item, similar to the PRE868. The T5 or T17 transducer
should be ordered without any junction box enclosure.
Specify option G=00 for either T5 or T17 (see below). All
XAMP enclosure options, as configured today, accept a
¾” NPT cable gland as standard. CSA certification is in
process and in place by the end of May 2013. This will
not affect ordering but may affect lead‐time.
The XAMP enclosure certifications are only valid when configured
with T5 or T17. Do not pair with any other transducer, as
certifications will not be valid.
The CBS 212A then provides full current boost to the generator exciter until
the voltage returns to a level just above the operating point setting.
The Controls and Indicators and Installation chapters provide information
about setting the Operating Point Adjustment.
An adjustable voltage limiting circuit prevents the Current Boost Module
output from exceeding the specified percentage of the nominal output
voltage (60. 120. or 220 Vdc). The Output Limit Select Jumpers are used
to select the nominal output voltage (60. 120. or 220 Vdc) and the Output
Limit Adjustment is used to set the desired percentage of the nominal output
voltage. The Output Limit Adjustment is adjustable over a range of 50 to
100 percent of the jumper-selected nominal output voltage.
| Basler Electric BE1-25 M9FA6PN4N0F / BE125M9FA6PN4N0F |
| Basler Electric BE1-50/51B-235 / BE15051B235 Self-Powered Time Overcurrent Relay |
| Basler Electric PLA2400-12GM / PLA240012GM |
| Basler Electric DECS 125-15-B2C5 DIGITAL EXCITATION CONTROL SYSTEM |
| Basler Electric BE1-851 Overcurrent Relay H5A2S1N |
| Basler Electric BE1-59N A6EE1JC0N1F Ground Fault Overvoltage Relay |
| Basler Electric BE3-25-1S1N4 / BE3251S1N4 Synchronizing Check Relays |
| Basler Electric L304KC / L304KC Camera Interface |
| Basler Electric SCA1300-32FC / SCA130032FC |
| Basler Electric BE1-27 A3EE1JA1N6F Voltage Relay |
| Basler Electric BE1-51 G1EZ1PA1N0FY Time Overcurrent Relay |
| Basler Electric 9073800-103 Power Supply 110/120v-ac 12.8a Amp 15v-dc |
| Basler Electric Relay BE1-50/51B-207 Overcurrent Relay |
| Basler Electric BE1-51-H5EZ2PB1N0F / BE151H5EZ2PB1N0F Time Overcurrent Relay |
| Basler Electric BE1-32-A1E-E1C-B0N0F / BE132A1EE1CB0N0F |
| Basler Electric BE1-81O/U T3ED1JB7N0F (AS PICTURED) NSNP |
| Basler Electric DGC-2020 Digital Genset Controller 100-480v-ac |
| Basler Electric SSR 63-12 Static Voltage Regulator 63VDC 100-139 VAC |