The M‑2067B is an adapter panel which, when combined with the M‑2001
Series Digital Tapchanger Control, provides convenient direct replacement
for Westinghouse SVC and SVR controls and Beckwith Electric M‑0067
series controls. The M‑2067B can also be used, with the M‑2001 Series
Tapchanger Control, as a general purpose LTC transformer control.
The M‑2067B permits changing of the M‑2001 control without adapter
panel removal or rewiring.
Adapts M‑2001 Series Digital Tapchanger Control to Replace Westinghouse
SVC and SVR Controls and Beckwith Electric M‑0067 Tapchanger Controls,
or as a General Purpose LTC Transformer Control
• Connects easily to the M‑2001 Series Digital Tapchanger Control using
four mounting screws and 24‑pin connector
• Provides mounting adaptable to several different configurations
• Provides built‑in CT shorting protection when the M‑2001 Series
Tapchanger Control is removed

Interface
External connections are made to two terminal blocks located on the rear
of the adapter panel. The second terminal block provides auxiliary functions,
including self‑test alarm, user‑programmable alarm, manual raise/ lower,
operations counter and ∆VAr 2 disable.
Testing Specifications
High Voltage: All input and output terminals will withstand 1500 Vac rms to
chassis or instrument ground for one minute with a leakage current not to
exceed 25 mA, for all terminals to ground. Input and output circuits are
electrically isolated from each other, from other circuits and from ground.
Surge Withstand Capability: All input and output circuits are protected against
system transients. Units pass all requirements of ANSI/IEEE C.37.90.1-1989
defining surge withstand capability.
Radiated Electromagnetic Withstand Capability: All units are protected against
electromagnetic radiated interference from portable communications transceivers
as outlined in ANSI/IEEE C37.90.2-1987 defining radiated electromagnetic
withstand capability.
• M-2948 Tap Position Sensor directly mechanically replaces the Selsyn-Type Tap
Position Sensor.
• Directly interfaces with a 4 to 20 mA output to the M-2025D Current Loop Interface
which provides the tap position to the M-2001 Series Tapchanger Control.
• Rotation – 0 to 210°, 297°, 306°, 315°, 325°, 330°, 340° and 350° configurations
• Degrees per Tap – 9° or 10°
• Neutrals – 1, 2, 3, 5 or 6
• Rotation Direction – Tap Position Sensors are available with either a positive
or negative rotation. With positive rotation, the shaft of the M-2948 rotates
clockwise while raising taps. With negative rotation, the shaft of the
M-2948 rotates counter-clockwise while raising taps.
The M‑2069 Adapter Panel, when combined with the M‑2001C or M-2001D
Digital Tapchanger Control, offers convenient, direct replacement of
Westinghouse SVC or SVR controls and Beckwith Electric M‑0067E controls
or M-2067B adapter panels.
The M‑2069-M-2001D combination can also be used as a general purpose
LTC transformer control.
Applications
• Connects easily to the M‑2001Series Digital Tapchanger Control using
four mounting screws and 24‑pin connector
• Provides mounting adaptable to several different configurations
• Provides built‑in CT shorting protection when the M‑2001 Series Digital
Tapchanger Control is removed
The M‑2053 is an adapter panel which permits M‑2001 Series Digital
Tapchanger Controls to be surface‑mounted while providing access points
for wire terminations.

Beckwith M-0193 Syncrocloser Unit |
Beckwith Electric generator protection system M-3420 STOCK G365 |
Beckwith Electric M-4272 Integrated Synchronizing Systems Motor Bus Transfer |
Beckwith M-0115A Parallel Balancing Module Made in USA. |
Beckwith M-3425 Integrated Generator Protection |
BECKWITH ELECTRIC M-3425A Generator Prothection |
Beckwith Electric M-3425A Integrated Generator Protection Relay |
BECKWITH ELECTRIC M-3425A INTEGRATED GENERATOR PROTECTION RELAY M-3425A |
Beckwith Electric M-3520 Intertie Protection Relay |
BECKWITH M-0193B SYNCROCLOSER UNIT (RR4) |
BECKWITH ELECTRIC M3420 GENERATOR PROTECTION RELAY |
BECKWITH / M-0245B HIGH SPEED SYNC-CHECK |
Beckwith Electric M-3420 Integrated Generator Protection Module |
Beckwith Electric M-3311A 8 Output D-0179 60-140 VAC Transformer Protection. |
Beckwith P-1939 Generator Protection Relay Annunciator Panel B-0898 Rev A-2 |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com