While the SLS 1508 Logic Solver is rated suitable for use in SIL 3 applications
in simplex mode, it is installed in redundant pairs for increased process availability.
Redundant SLS 1508 Logic Solvers run in parallel at all times.Both read the inputs
from the I/O terminals, both execute the logic and both drive the outputs at the I/O terminals.
There is no concept of primary and backup or master and slave,which is unlike any other SIS.
The only difference between the two is that one communicates with both the engineering
and operator workstations and the dedicated safety network (SISNet);
this is the one with the Active light on the bezel.The other (Standby) is
communicating only on the SISNet.In the event that a failure is detected in
one of the SLS 1508 Logic Solvers, it automatically goes to a failed state.

In this condition, all its output channels are de-energized;
this has no impact on the other SLS 1508 Logic Solver or the physical
outputs because the other SLS 1508 Logic Solver continuesto read inputs
execute logic and drive outputs. The transition from redundant to simplex
mode is therefore completely bumpless.
The redundant SLS 1508 Logic Solver modules are connectedto the field at the redundant
terminal block. No control strategy configuration is required to take advantage
of SLS 1508 Logic Solver redundancy, as the system’s auto-sense capability
automatically recognizes the redundant pair of Logic Solvers.
An integrity error alarm in a redundant SLS 1508 Logic Solver pair will notify
the operator of a failure. Both SLS 1508 Logic Solvers in a redundant pair
are monitored for integrity alarms at all times.
Events that can cause integrity alarms include:
• Hardware failure within a SLS 1508 Logic Solver
• Communications failure between a SLS 1508 Logic Solver and the SISNet
• Communications failure between a redundant pair of SLS 1508 Logic Solvers
• Communications failure between a SLS 1508 Logic Solver and an DeltaV Controller
• Removal of a SLS 1508 Logic Solver from the carrier
EMERSON PMC PROFINET Industrial Network Interface Module
EMERSON PMC-IO-PROZESSOR Industrial Controller Module
EMERSON PMC-IO-ADAPTER Adapter/Carrier Converter card
EMERSON DB1-1 Industrial Controller Module
EMERSON VE3007 KJ2005X1-BA1 12P4375X012 Industrial Controller Module
Emerson A6140 9199-00058 Digital Valve Controller
EMERSON A6824R 9199-00098-13 Industrial Control Module
EMERSON 5X00502G01 Ethernet Communication Interface Module
EMERSON 5X00500G01 Ethernet Communication Interface Module
EMERSON KJ3002X1-BF1 12P1732X042 Analog Input Card RTD
EMERSON 1C31234G01 "Digital Input Electronics Module"
EMERSON 9199-00002 A6120 Monitoring Module
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2026 Cld , All Rights Reserved K-JIANG All rights reserved