Emerson Controlinc Network Masters are the master of Emerson Controlinc valve
actuator networks with Modbus RTU protocol. The system provides network management,
data concentration and protocol conversion, off-loading the host system of these tasks.
This enhances overall system performance and minimizes software development and
system configuration tasks by the system integrator. The Network Master serves as the
master of a master/slave network. It manages the network by keeping an orderly cycle of data
transfers to and from the slave devices (valve actuators). It handles error detection, alarming,
and network recovery. The Network Master serves as a data concentrator for the host by
providing a common database for all slave devices. The host is required to communicate
with only one slave device (network master) for all data transfers to and from the field.

Data can be transferred between the network master and host in large blocks at a much
higher communications rate than would be possible if the host communicated with each
slave device (valve actuator) on the field network. The Network Master acquires data from
the valve actuators by polling or scanning each device in a sequence of slave address from
a table called a scan list. Polling is a process of the Network Master sending to each slave
address, a command to return its status information, including alarms, discrete and analog
inputs and outputs. When control commands (valve open, stop, close, position set point, etc.)
are generated by a host system up-line of the Network Master, it then sends the appropriate
commands over the network to the addressed slave device. A more detailed functional
description of operation is provided in the Theory of Operation section of this manual.
System Configuration
Controlinc Network Master Model M250N contains redundant valve actuator network masters
in a single enclosure. M250N supports one Controlinc E>Net ring network with up to 250 valve
actuators. Options for support of redundant bus networks and redundant E>Net rings are also
available. The supplied system uses standard RS485 and Modbus RTU protocol for the valve
actuator networks. Ethernet TCP/IP encapsulated Modbus protocol connections are provided
for redundant host computer networks. The Ethernet links are IEEE 802.3 with RJ45 connectors
for 10/100Base-TX. Protocol is Ethernet v2 encapsulation TCP/IP Version 4.