Internal or external triggering is possible.
Measurement time is 0.8 seconds for a span of 200 nm and varies with the span.
Broadband light sources with a resolution of 5 nm have the highest sensitivity,
while narrowband light sources (lasers) can be reliably analyzed down to the noise level even with a narrow resolution bandwidth.
The normalization function combined with the white light source allows direct measurement of transmission and loss characteristics of filters and fibers.
Operation
In addition to amplifier analysis, a variety of display modes are available, such as
- Overlay display,
- Comparison with memory contents,
- Display of two independent graphs (split screen),
- Power meter function,
- Use of multiple markers,
- Normalized and direct readout of transmission loss and
- Automatic bandwidth analysis (e.g. measurement of half-value widths based on RMS and envelope methods),
- Curve fitting over the IEC/IEEE bus and many other features facilitate operation of the analyzer and simplify analysis.
Measurement time is 0.8 seconds for a span of 200 nm and varies with the span.
Broadband light sources with a resolution of 5 nm have the highest sensitivity,
while narrowband light sources (lasers) can be reliably analyzed down to the noise level even with a narrow resolution bandwidth.
The normalization function combined with the white light source allows direct measurement of transmission and loss characteristics of filters and fibers.
Brief Description
The Q8383 is an advanced spectrum analyzer (Advantest) with a two-pass monochromator and very low polarization dependence.
Thanks to a special method, values of ±0.05 dB are guaranteed, with typical values as low as 0.02 dB.
Together with the high accuracy of the resolution bandwidth, the Q8383 can be used to perform precise power measurements.
All of these features make the Q8383 an ideal measurement instrument for erbium-doped fiber amplifiers (EDFAs).
By simply comparing the signal at the input of the amplifier with the signal at the output of the amplifier,
special measurement functions can be used to determine the noise figure, gain and spontaneous emission.
Of course, all these functions are also of great advantage when measuring laser diodes, light emitting diodes and other light sources.
The curve fitting function directly displays electroluminescence characteristics by fitting a Gaussian distribution to the emission spectrum.
This is very useful for measuring Erbium Doped Fiber Amplifiers (EDFA) and Light Emitting Diodes.
A special feature for pulsed light allows measurements of fiber optic rings and soliton transport systems.
Recommended Products P/N:
Advantest BGC-022641 Memory RAM PGC-622641BB2 Module 01537 |
Advantest BGC-024741 |
Advantest BGD-02097 BOARD |
Advantest BGD-022241 BA BOARD |
Advantest BGD-022242 BB BOARD |
Advantest BGD-022555 PGD-422555BB2 |
Advantest BGD-023054 BGD023054 |
Advantest BGD-024401 for M6541AD |
Advantest BGD-026363 FedEx 90days Warranty |
Advantest BGG-029070 _ PPG-829070DD _ TKK-5 BOARD |
Advantest BGK-024673 board |
Advantest BGL-015413 Board_Used_Japan_95862 |
Advantest BGR-017417 PCB_ HVPPS CONTROL |
Advantest BGR-024356 TGFC I F BOARD |
Advantest BGR-024841 PCB 1998 f r Eine T5371 |
Advantest BIR-026382 Tabla - Fair Condici |
Advantest BIR-26805 Board |
Advantest BLB-017407 GPIB Connector Card Board A1910ZB |
Advantest BLB-019431 Fan Rotation Sensor PLB-219431AA1 JAP |
Advantest BLB-025841 Circuit Board PCB PLB-420972BB2 M4542 |
Advantest BLB-027895 Circuit Board PCB PLB-420972BB2 M4542 |
Advantest BLC-015681 Tracking generator for R3361A R3361B_ |
Advantest BLC-029524 PCB Circuit Board M4542ADg |
Advantest BLD-024486 Processor PCB Card PLD-424486CC |
Advantest BLG-015240 Board_Used_Japan_95863 |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved