Modern digital devices offer a wide range of configurable settings
to meet diverse application needs. With so many parameters and
functions available,it is essential to have a user-focused interface.
BESTCOMSPlus® delivers that, helping users visualize device
configurations, and confidently manage system interactions for
commissioning, operation, and diagnostics.

BESTCOMSPlus® is used to set and monitor the BE1-FLEX, BE1-700V,
BE1-11. DECS-150. DECS-250. DECS-250E, DECS-250N, DECS-450.
DGC-2020.DGC-2020ES, and DGC-2020HD.
An economical, microprocessor-based relay designed to replace out of
date, aging electromechanical relays, with models to replace existing
GE and ABB relays with no wiring changes. Basler Electric also offers
the BE1-79A in an S1 case for new installations.
A terminal voltage limiter within the IFM-150 can be enabled to
monitor the generator voltage through the synchronizing
transformer or external voltage transducer and compare the
measurement with a user adjustable reference level.
If the generator voltage exceeds the reference level for a user
-adjustable amount of time, the IFM-150 will modify the SCR
firing pulses and limit the generator voltage.
The BE1-CDS240 Current Differential System is an economical,
microprocessor based, multifunction system that provides a four
input, three-phase percentage differential with harmonic restraint
protection.
Also included is three-phase with voltage control, ground, and
negative-sequence overcurrent protection, voltage and frequency
protection, breaker failure for up to four breakers, breaker monitoring
for four breakers, transformer monitoring, and metering functions,
all in an integrated system with several communications options.
The BE1-CDS240 Current Differential System is intended for use in
any low impedance current differential protection application including
transformer, generator, motor, and bus protection.
Four setting groups are provided for adaptive relaying with automatic
selection logic for cold load pickup and/or dynamic setting group changes.
The BE1-CDS240 can be ordered with 12 programmable contact sensing
inputs, 10 programmable outputs, and one alarm output or eight
programmable contact-sensing inputs, 14 programmable outputs and
one alarm output. Outputs can be assigned various functions by logical
programming to perform protection, control, or indicate operations.
Basler Electric 9289902106 Circuit Board Rev A
Basler Electric 9105100106 UFOV-250A Under Freq./Overvoltage Protector
Basler Electric BE1810/U-2 Solid State Frequency Relay BE1810
Basler Electric BE1-67 Ground Directional Overcurrent Protective Relay
Basler Electric 1783 Be1783 Contactor Dc Current Transformer Coil, 1200:5A Ratio
Basler Electric BE25927001 Current Transformer - 1:34 Amp - Tested/1Yr Warranty
Basler Electric BE1-25/ BE1-25M1GA6PN4R3F STOCK G277
Automatic Voltage Regulators DECS100-B15 For Basler Electric Generator
Basler Electric BE3-47N/27-3A4N2 9320400101 120V
Basler Electric Solid State Protective Relay BE1-60
Basler Electric SSR 63-12 STATIC VOLTAGE REGULATOR 600VAC 50/60HZ 9 1859 00 101
Basler Electric SR8A2B01A3E Static Voltace Regulator
Basler Electric PCB Assembly 9059701100 919620
Basler Electric F3EE1PA0N1F BE1-40Q
Basler Electric BE1-81-O/UT3ED1JB6N0F / BE181OUT3ED1JB6N0F