Some standard configurations allow as an option admittance-based, harmonics-based or wattmetric-based earth-fault protection to be
used in addition to directional earth-fault protection.
Further, the IED features sensitive earth-fault protection, phase discontinuity protection, transient/intermittent earth-fault protection,
overvoltage and undervoltage protection, residual overvoltage protection, positive-sequence undervoltage
and negativesequence overvoltage protection.
The outstanding I/O capability in REC670 enables control of several bays with complete measurement with only one IED.
For instance, one REC670 IED is capable of handling control of all apparatuses
in one entire diameter in 1 ½ breaker arrangement including breaker failure protection for all breakers.
The REF 543 feeder terminal is designed for protection, control,
measurement and supervision in medium voltage networks.
The REF 543 feeder terminal can be used with different kinds of switchgear,
including single busbar, double busbar and duplex systems.
The protection functions also support different types of networks, such as, isolated neutral networks,
resonant-earthed networks and partially earthed networks.

RET670 IEDs provide customized or pre-configured protection solutions for any type of transformer and shunt reactor application.
The customized RET670 gives you the freedom to select functionality entirely according to your needs.
The pre-configured RET670 variants simplify handling since the basic functionality is included and pre-configured.
If needed, you can add optional functions to increase the functionality of the pre-configured RET670
IEDs to meet the specific requirements of your transformer or shunt reactor.
The extremely fast differential protection function with automatic CT ratio matching and vector group compensation,
makes RET670 the ideal solution for the most demanding applications.
Furthermore, one RET670 IED can be extended to contain two differential protection functions to protect the most advanced system configurations.
This transformer protection IED is designed to operate correctly over a wide frequency range in order to accommodate
power system frequency variations during disturbances and generator start-up and shut-down.
It has very low requirements on the main CTs, and no interposing CTs are required.
RET670 features also several functions for local and remote apparatus control on all sides of the transformer.
Secure bay and station wide interlocking allows you to avoid dangerous or damaging switchgear operations and to ensure personnel safety.