PMK22 Plates Coupler Module Manufacturers ABB, Hartmann & Braun Model(s)
ABB H&B Contronic, ABB H&B Contronic P
Estimated Shipping Size Dimensions: 5.0" x 1.0" x 10.0" (12.7 cm x 2.5 cm x 25.4 cm)
Weight: 0 lbs 7.1 oz (0.2kg ) PMK 22
Tmax T5 to Tmax T8 have undergone a severe sequence of test in accordance to UL 489 to obtain UL listing and UL marking.
Certification in accordance to UL 489 has been extended to the most common accessories as well.
Tmax T5 and T6 are the molded case circuit breakers with the best performance/size ratio.
T5 offers a maximum short circuit breaking capacity of 150kA at 480V and 100kA at 600V.
T5 and T6 have the same depth, simplifying their positioning in the switchboard compartments, and share the same internal electrical accessories.
Thermalmagnetic and electronic trip units make T5 and T6 suitable for AC and DC applications.

Tmax T7 is available in two versions up to 1200 A either with operating toggle or in motorizable version.
Electrical performances are consistent with the rest of the range with a maximum breaking capacity of 100kA at 480V and 65kA at 600 V.
A wide range of dip switches and LCD electronic trip units can be selected according to plant requirements.
Tmax T8 covers 2000 A, 2500 A and 3000 A frame sizes breaking capacities of 125 kA at 480 V and 100 kA at 600 V.
It is equipped with PR331/P and PR332/P, same electronic trip units as Tmax T7.
thereby guaranteeing extremely high performances able to satisfy all installation requirements.
Adequately sized for the performances offered, it is supplied as standard with front terminals up to 2500 A,
whereas the 3000 A frame is always supplied with rear vertical terminals.
Tmax molded case circuit breakers tested and certified in accordance to UL 489 and CSA C22.2 carry IEC marking as well,
so they are the perfect solution for those OEMs looking for a product that is globally recognized and accepted.
COMPLETE AND PERFECTLY INTEGRATED
In the range of molded case circuit breakers conforming with the
UL 489 and CSA C22.2 Standard, ABB SACE proposes an entire
range which covers continuous current ratings between 15 A and
2500 A and interrupting ratings, at 480 V AC, which can reach 100 kA.
The ranges available are as follows:– circuit breakers for power distribution (fitted with thermomag
netic or electronic trip units starting from 100 A)– circuit breakers with adjustable magnetic only trip units for
motor protection (MCP: Motor Control Protection)– molded case switches for use as isolators or switching devices
for lines, busbars or parts of a plant (MCS: Molded Case Switch)
With the introduction of the new Tmax UL series, a single-pole
circuit breaker with interrupting rating of 18 kA at 277 V AC is
available on the American market for the first time.