Power System Fan Manufacturers ABB, Bailey Model(s)
ABB Bailey Infi 90, ABB Bailey Infi 90 and Net 90
Additional Information 24 VDC, 5.6 A, 25.5 VDC OUTPUT, 120/240 VAC, 125 VDC INPUT
Estimated Shipping Size Dimensions: 9.0" x 7.0" x 16.0" (22.9 cm x 17.8 cm x 40.6 cm)
Weight: 5 lbs 9.0 oz (2.5kg )
Tariff Code: 8504409540
Country of Origin: United States Ships from Webster NY, USA
Power System Fan
Symphony Plus Control & I/O BRC410
ƒ Performance increase depends on specific
function blocks used, but in general
performance of latest module (BRC410)
compared with older modules:
ƒ ~ 10x vs. MFP01/02/11/12
ƒ ~ 4x vs. BRC100/200
ƒ Enhanced On-Line Configuration provided
by BRC410
ƒ BRC410 also provides ModBus TCP
ƒ BRC410 support 30,000 block addresses
and 4,000 Modbus TCP/IP points
ƒ Infi90 Modulebus support*
ƒ Downloadable firmware
Power Entry Circuit Breaker or Switch
The IPECB11 or IPECB13 Power Entry Circuit Breaker and IPESW11 or IPESW13 Power Entry
Switch terminate the AC or DC power input lines and provide line filtering before feeding power
to the power module chassis backplane. These devices mount on the back of the power fan chassis.
One circuit breaker or switch is used on N, N+1, and N+x redundant systems (Fig. 2); two are
used on 2N redundant systems (Fig. 3). The isolated inputs on 2N redundant systems allow for
mixed power inputs (i.e., 125 VDC and 120/240 VAC) because two separate power entry circuit
breakers or switches feed isolated power inputs to the power module chassis.
Fan Chassis and System Fans
The IPFCH01 Power Fan Chassis mounts two system power fans. There is one types of fan used in
the Modular Power System II. It is the IPFAN14 (120/240 VAC, 125 VDC).
The fan chassis provides a power connection, and fan monitoring and control via a cable connection to the power module chassis backplane.
The power system fans mount side-by-side in the fan chassis.
Hall effect sensors on the power system fans provide fan speed information to the power monitor module.
Fan speed is controlled as a function of cabinet temperature. One fan is capable of cooling the cabinet and a failed fan can be
replaced while the system is on-line.
Features and benefits
Termination for up to eight (8) analog I/O process signals within a horizontal row.
All SD I/O modules & bases of all types (Singular or Redundant) AND (Compact or Full-size), are
100% fully compatible with each other. Thus, Singular & Redundant, Compact or Full-size I/O
modules can be mounted within a single, common HN800 I/O bus.
Optional mechanical keying can be implemented to prevent insertion of the wrong I/O module type.
Latching device on the base locks the base into position on DIN-Rail.
Industry standard 35-mm DIN rail, Horizontal row mounting.
ABB HIEE305084R0001 UNS 0861 A-PV1 power supply
ABB HIEE305084R0002 UNS 0861 A-PV2 power supply
ABB HIEE405179R0001 UNS 0862 A-PV1 Analog input/output
ABB HIEE405227R0001 UNS 0864 B-PV1 diode monitoring
ABB HIEE405167R0001 UNS 0865 A-PV1 Power System Stabilizer
ABB HIEE405246R0001 UNS 0867 A-PV1 I/O extension card without analog signal
ABB HIEE405246R0002 UNS 0867 A-PV2 I/O extension card with analog signal
ABB 3BHE01 3940R0001 UNS 0868 B-PV1 power supply
ABB 3BHE01 3940R0002 UNS 0868 B-PV2 power supply
ABB 3BHB001337R0002 UNS 0869 A-PV2 Power System Stabilizer
ABB 3BHB002651R0001 UNS 0874 A-PV1 Control Panel
ABB 3BHE004059R0104 SDCS-CON 2-21 Motherboard
ABB 3ADT315100R1012 SDCS-POW 4 internal power supply
ABB 3BHE006422R0001 UNS2861 C-P, V1 HGC door control unit