Mounting of Rack Mount Enclosure
The enclosure is designed for standard EIA 19 in. DIN rail rack mounting. Dimensions of the
enclosure are shown in Figure 7. The enclosure conforms to EIA RS-310. IEC 297-1. and DIN 41
494. Part 1 standards. The rack in which the enclosure(s) are mounted must allow a minimum
of 20 in. / 508 mm depth, allowing space for cable connections. If the system includes backup
LCD keypad terminals, some planning is required to allow for proper height above the floor to
view the display and operate the keypad properly.

The DeltaV™ S-series hardware takes the proven DeltaV
hardware to a new level of robustness and ease of use.
Assembly is faster and power distribution is easier, with fewer
connections using the integrated field power distribution and
increased capacity of I/O bus power.
The field network is wired in a ring configuration from Port A around a loop to Port B of the
network master. Beginning at Port A, the network is wired to Port A of the first actuator and
then from Port B of the first actuator to Port A of the second actuator and so on until the
network returns from Port B of the last actuator to Port B of the network master. Networks
may have parallel wired (bus wired) actuators between series wired actuators. Always wire
parallel actuators to Port A and remove termination and bias. Do not connect more than 15
actuators in parallel between any two series connected actuators. Networks are polarized with
(+) and (-) symbols on all drawings. Proper operation requires that polarity be observed at all
connections. Connect the field networks to the Port A and B connectors on the NIM in the
network master as shown in Figure 9. The networks must be connected to Port A and Port B
of the valve actuators as shown in the wiring diagram of the XTE3000/ICON3000 IOM. Others
320B and RTS, please refer to their IOM for network wiring diagram. Controlinc 320B Quick
Start manual. Controlinc supports many different network topologies. This manual supports
only a single ring E>Net network topology that allows a combination of parallel (bus) and series
E>Net connections on the same network.
Foxboro FPS400-24 P0922YU Standard 200 Series Power Supply
Foxboro RH101AA Industrial Control Module
Foxboro H90C9AA0117S Compact programmable logic controller
Foxboro H92A049E0700 Workstation for Windows Operating Systems
Foxboro RH931RQ Cable Terminal
Foxboro E69F-BI2-S Current-to-Pneumatic Signal Converter
Foxboro P0926JM 8 Position Modular Baseplate
Foxboro E69F-T-I2-JRS Current-to-Pneumatic Signal Converter
Foxboro B4H254-8F8T X440G2-12T8FX-GE4 Industrial Control Module
FOXBORO A4H254-8F8T P0973JP Managed Ethernet Switch