The DriveBus protocol is used to communicate with ABB Drives and ABB Special I/O units.
DriveBus is connected to the controller via a CI858 communication interface unit.
The DriveBus interface is used for communication between ABB Drives and AC 800M controller.
The DriveBus communication is especially designed for sectional drive applications for
ABB rolling mill drive systems, and ABB paper machine control systems.
The CI858 is powered by the processor unit, via the CEX-Bus, and therefore does not
require any additional external power source.
Features and benefits
DriveBus supports Hot Swap A maximum of 24 ABB drives can be connected
to one CI858 and a maximum of two CI858 can be connected to an AC 800M controller.
If more than one ABB drive is connected to the CI858, a branching unit NDBU is needed,
which enables the construction of a logical bus with physical star topology.
The branching units can be chained.
Select Main menu/Settings.
• LHMI messages are shown in Courier font.
To save the changes in non-volatile memory, select Yes and press .
• Parameter names are shown in italics.
The function can be enabled and disabled with the Operation setting.
• Parameter values are indicated with quotation marks.
The corresponding parameter values are "On" and "Off".
• IED input/output messages and monitored data names are shown in Courier font.
When the function starts, the START output is set to TRUE.
APPLICATION
The REF543KM127AAAA is a feeder terminal produced by ABB that is used in a wide range of applications.
Designed for protection, control, measurement and monitoring of medium voltage networks,
the device can be used with different types of switchgear, such as single bus,
dual bus and dual machine systems, and supports a variety of network types, including isolated neutral networks,
resonant ground networks and partially grounded networks.
It is especially suitable for the protection and control of medium-sized three-phase asynchronous motors,
as well as the protection and control of shunt capacitor banks for reactive power compensation.
GE 8603-FT-FU Field terminal, non-incendive, fused (Div 2)
GE 8619-FT-MT 44-pin Mass Termination Assembly (Div 2)
GE 8604-FT-FU Field terminal, fused
GE 8620-FT-MT Field terminal assembly
GE 8605-FT-TC Field terminal, thermocouple
GE 8621-FT-IS Intrinsically Safe Field terminal, standard
GE 8606-FT-RT Field terminal, RTD
GE 8622-FT-IS Intrinsically Safe Field terminal, loop-disconnect (not for 8 channel DI)
GE 8607-FT-TC Field terminal, 8-channel with T/C
GE 8623-FT-IS Intrinsically Safe Field terminal for 8220-DI-IS
GE 8608-FT-NI Field terminal, 8-channel, non-incendive
GE 8624-FT-IS Intrinsically Safe Field terminal with loop-disconnect
GE 8610-FT-NA Field terminal, non-arcing (Div 2)
GE 8625-FT-I SIntrinsically Safe Field terminal, THC
GE 8611-FT-FU Field terminal, non-arcing, fused (Div 2)
GE 8626-FT-IS Intrinsically Safe Field terminal, RTD
GE 8612-FT-NA 16-channel Field terminal, non-arcing
GE 8632-FT-NI 32-channel Field terminal
GE 8615-FT-4W Field terminal, 4wire (current sinking)
GE 8650-FT-PX 32-channel PX/Switch FTA for 8125/7
GE 8616-FT-FU PAC8000 Field terminal, fused