RCC972 – RCC Controller with eight (8) Digital inputs compatible with 12V/24VDC – four (4) DC Outputs
– .5A per point – Eight (8) 12-bit Analog Inputs 0-20mA and four (4) 12-bit Analog outputs 0-20mA
8 digital DC inputs, 4 digital outputs, 8 Analog Inputs and 4 analog outputs,
providing users with superior I/O options for a wide range of Process and Discrete Manufacturing applications
Provides superior connectivity – supporting both CAN and 10/100 Ethernet as standard
Inclusion of CAN provides the ability for the RCC to support hundreds of remote I/O points using Horner’s CsCAN
Digital & Analog Information
Digital Filtering module response to a temperature change.
The illustration above demonstrates the effect of digital filtering on (set with Filter Constant).
Analog Input - Raw input values for channels 1-4 are found in the registers as Integer-type data with a range from 0 – 32000.
Analog inputs may be filtered digitally with the Filter Constant found in the Cscape Hardware Configuration for Analog Inputs.
Valid filter values are 0 – 7 and act according to the following chart.
CAN Communications
The CAN port is provided via two connections: CAN_LOW (CL) and CAN_ HIGH (CH).
It may be used to communicated with the other OCS products using Horner’s CsCAN protocol.
Additionally, remote expansion I/O, such as SmartRail, SmartBlock, and SmartStix may be implemented using the CsCAN protocol.
If CsCAN expansion I/O is to be used, a 24VDC power source will be required on the CsCAN bus in order to power the expansion I/O modules.
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved