The HCU16 HART units connect to 16 general purpose field instruments
while maintaining channel to channel isolation. Resistor conditioning
options are compatible with all types of I/O cards. It allows pass-through
connections for transmitter power supply, input signal and common.
The HCU16AO unit includes HART filters for use with I/O cards that are
incompatible with HART communication signals.
Customised backplanes and connection units are available to provide
direct connection from DCS I/O cables, replacing the standard termination
boards.
See also the MTL4850 datasheet for alternative HART solutions using a
32 channel multiplexer module ideally suited for use in conjunction with
emergency shutdown and safety systems.
Connectivity to HART Configuration and Instrument Management
Software :
The online access to the information contained within HART devices
allows users to diagnose field device troubles before they lead to costly
problems. Software can capture and use diagnostic data from HART
field instruments via the MTL HART connection hardware. This allows
users to realise the full potential of their field devices to optimise plant
assets, which results in significant operations improvement and direct
maintenance savings.
IMS products provide essential configuration, calibration, monitoring
and maintenance history functions for conventional analogue (4-20 mA)
and HART protocol compatible smart process instruments and field
devices. They deliver powerful tools to meet the need for standardised
instrument maintenance procedures and record keeping mandated by
some quality standards and regulatory bodies.
The MTL4851 and MTL4852 modules can also be located on HTP
SC16x termination boards for general purpose applications. HART loops
are simply wired through these HART Termination Panels and may be
grounded or floating circuits. The HTP boards offer a compact and cost
effective solution for general applications. CPH-SC16x backplanes are
ideal for signal loops requiring intrinsic safety (IS) protection, combining
multiplexer and IS isolator mounting. This offers considerable simplification
in wiring when compared to DIN-rail based solutions.
The HCU16 HART units connect to 16 general purpose field instruments
while maintaining channel to channel isolation. Resistor conditioning
options are compatible with all types of I/O cards. It allows pass-through
connections for transmitter power supply, input signal and common.
The HCU16AO unit includes HART filters for use with I/O cards that are
incompatible with HART communication signals.
Customised backplanes and connection units are available to provide
direct connection from DCS I/O cables, replacing the standard termination
boards.
Eaton WL-35717F Vacuum Interrupter WL35717F
Eaton MFD-CP8-NT Central processing unit/power supply unit
Eaton MP-3000 Motor Protection Relay
Eaton HMCP400R5 HMCP400R5 Circuit Breaker
CUTLER HAMMER / Eaton 7801C57 Digitrip Optimizer Hand Held Programmer
Eaton HMCP150U4 molded case circuit breaker accessory motor protection
EATON SDN90186 MOTOR CONTROL CENTER
EATON CEAG CU CG-S , 40071360300 Control Unit
Moeller XV-230-57CNN-1-13-1 HMI PLC Panel Touchscreen 5.7" Operator Terminal
Eaton Cutler-Hammer HFD3030 6639C86G87 3 Pole 30A 600V Circuit Breaker
Eaton HFD3150 3P 150A 600VAC Circuit Breaker
EATON MP-3000 66D2032GX1 NSNP
EATON XV-102-B5-35TQR-10-PLC 140021 XV102B535TQR10PLC