The EBR-3000 relay, combined with an EBR-Z (EBR-3Z), is a digital
protection relay designed for high impedance differential protection
schemes . The intuitive operating system with validation checks and
extensive commissioning functions such as the built-in fault simula
tor allow safe and time-optimized maintenance and commissioning .
The parameter setting and evaluation software PowerPort-E can be
used consistently across the entire family of E-Series relays .

The principle of the high impedance differential protection is compa
rable with low impedance differential protection: Calculate and moni
tor the sum of all the currents flowing into the protected object, and
under non-fault conditions the sum is zero . Any differential current,
however, is forced through the high impedance of the high imped
ance relay .
The input of the high impedance relay consists of a resistance
(EBR-Z) and an overcurrent protection element (ANSI 87 in the EBR
3000) .
The following convention is important to know: Even though the
EBR-3000 measures the currents flowing through the stabilizing
resistor, all the measurements are presented as a voltage across
this stabilizing resistor (which is 2000 Ω for the EBR-Z) . The burden
of the EBR-3000 measuring input (which is in series with the EBR-Z
resistor) can be neglected compared to the 2000 Ω impedance .
The EBR-3000 monitors the magnitude of this voltage to differenti
ate between in-zone and through faults .
A varistor is built into the EBR-Z . It is connected across the input of
the relay to avoid damage to the relay caused by high voltage . The
varistor needs to be able to conduct significant power as the paral
leled CTs deliver current under special fault circumstances (e . g . in
case of a breaker failure) for more than 30 cycles .
To prevent damage to the relay due to system issues, a lockout relay
is required to short-circuit the high impedance when an trip is initi
ated .
The F810 fieldbus power system is designed to provide redundant
Foundation™ fieldbus power for Foxboro I/A Series control systems
using FBM228 modules. Eight fieldbus segments are supported. The
system comprises a baseplate which accommodates two redundant
pairs of Foxboro FBM228 modules and two Eaton F801 or F802 power
modules operating in redundant configuration. Failure alarms, galvanic
isolation, power conditioning and segment termination are incorporated
into each F80x module. In applications requiring simplex power, a single
F80x module may be used.
The Power Xpert® energy meter series power and energy meters monitor
the most critical aspects of an electrical distribution system. This premier
metering instrument uses the latest in advanced technology to make it
simple to use, powerful, scalable, and highly flexible.
Eaton’s Power-Sure 700 is a tap changing transformer that can solve
99 percent of electrical disturbance problems to better protect your
equipment. This computer-grade, three-phase transformer features
standard and advanced metering with 97 perfect efficiency.
Combining the reliable frequency regulation you expect from an
Eaton tap changing transformer with high frequency filtering and
an optional manual bypass switch, the Power-Sure 700 is the ideal
transformer for any industrial application.
| EATON MTL E05016 DIGITAL INPUT EUROCARD E05516-2134 |
| EATON MOELLER DILM250/22(RA250) contactor |
| Eaton Cutler-Hammer 2D78559G01 Rev.11A, Universal RTD Module |
| Eaton OFT-10W01 CGLine+Web-Controller 400 71 777997-J |
| EATON CGLINE + WEB-controller 400 71 361 055 |
| EATON DURANT 57151-400 RATE METER 57151400 |
| EATON CORPORATION KRP-C-1100SP FUSE |
| EATON GHG5124407R3001 CROUSE HINDS SERIES WALL SOCKET |
| EATON PXM4251A1BB Power Xpert meter 4000 |
| EATON XV-102-D0-70TWR-10 TOUCH PANEL, PN:142535, 24VDC 0.4A, NNB |
| EATON XV-102-B5-35TQR-10-PLC / Version: 04 Touch Pane |
| Eaton Moeller NZM10-400N Circuit Breaker NZM10400N |
| EATON DURANT 58820-400 TOTALIZER 5882-0 58820400 |
| EATON COOPER Crose-Hinds 9373-FB-PS-SS-040, MTL field bus barrier system 12-Spur |
| Eaton Vickers EEA-PAM-513-A-33 Replace of EEA-PAM-513-A-32 Power Amplifier |
| Eaton Crouse Hinds CLD Programmer /Field Unit P/N.T6527-50-03-00 |
| EATON CORPORATION 104-1193-006 MOTOR |
| Eaton ELC-EX16NNDR Programmable Logic Controller Digital Expansion Module 16 I/O |
| Eaton ELC2-PV28NNDR PV Controller, 28 I/O, 16 DI, 12 RO |
| EATON CORPORATION CAN-16DI/P / CAN16DIP STOCK 1276-A |
| Eaton ELC-PA10AADR ELC Logic Controller, 10 I/O |
| EATON ELCPV28NNDR CONTROLLER 28I/O 16INPUT DC 120OUTPUT RELAY |
| EATON EX16NNDRW4520024 Logic Controller Module 250VAC 50/60HZ 1.5A |
| EATON CEAG CU CG-S , 40071360300 Control Unit |
| EATON 40071361110 CEAG LP-STAR UNIT, 220-240V INPUT/OUTPUT |
| Eaton ELC2-PV28NNDR-2 AND ELC-EX16NNDR-2 Programmable Logic Controller |
| EATON MTL CP-DYNB-DI 16CH DI FTA CC Base Board,MTL16ATEXCPDYNX |