The active voltage regulation concept intends to substitute a traditional
voltage regulation configuration by simplifying the overall topology. The
easYgen internal controller regulates generator output voltage by sending a
pulse width modulation (PWM) signal to the excitation module. The excitation
module controls generator excitation and therefore generator output voltage.
This topology eliminates the redundant voltage and current sensing from a
traditional voltage regulator and also makes a feedforward control architecture
at AVR level simplifying the cascaded PID control topology. For power input,
EX-10 interfaces with any of the following excitation systems: Self/Shunt
Excitation, Auxiliary winding/AREP Excitation and Permanent Magnet (PMG)
Excitation systems to make it a standard yet versatile solution.

For redundant operation, the control can use any combination of power supplies.
The power supplies can only be installed into slots PS1 (power supply #1) and PS2 (power supply #2). If
redundant power supplies are not needed, blanking plates must be installed in the slots not being used.
Branch circuit fuses, circuit breakers, and wiring must meet appropriate codes and authorities having
jurisdiction for the specific country (CE, UL, etc.). See Table 4-3 for maximum recommended fuse or
breaker ratings. Do not connect more than one main power supply to any one fuse or circuit breaker. Use
only the wire sizes specified in Table 4-3. which meet local code requirements. Time delay fuses or circuit
breakers must be used to prevent nuisance trips.
In the event that on supply needs to be replaced, the recommended method for changing
Power Modules is with the power off (to the module being removed and the module being inserted).
The system will tolerate this “cold swap” method without failure.
Each main power supply has four LEDs to indicate power supply health (OK, Input Fault,
Overtemperature, and Power Supply Fault).
See MicroNet Plus Power Supply Troubleshooting (Section 5.5) for a description of the LED indications.
Input power connections are made to the power supply through a plug/header assembly on the front of the power supply.
| AEG 120-166-006 MODICON BRUSHLESS SERVO MOTOR |
| AEG Modicon Adapter Assembly AS-J540-100 |
| Modicon AEG AS-884A-201 Controller AS884A201 |
| AEG MODICON 24 VDC OUTPUT B824 |
| AEG Gould Modicon AS-B984-100 High Speed Discrete PLC ASB984100 Schneider |
| AEG Modicon MM-PMC2-10S PanelMate Plus Operator Interface Screen 92-00429-05 |
| AEG AS-B824-016 Modicon |
| AEG MODICON J892 ASCII REMOTE I/O PROCESSOR AS-J892-001 |
| AEG / MODICON AS-P892-000 REMOTE I/O PROCESSOR AS-9541-000 110/120V 50/60HZ |
| AEG Modicon AM-S980-810 MAP 3.0 Network Interface Controller Module PLC Gould |
| AEG Modicon ADU 214 Analog Input Module AS-BADU-214 |
| AEG MODICON PC-E984-685 984 CPU 16K MEM2XMB MB |
| AEG Modicon MM-PM10-200 Panelmate Plus |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved