Multilin™ G60
Comprehensive Protection for Generators
The Multilin G60 generator protection system provides comprehensive protection for medium and
large generators, including large steam and combustion turbines, combined-cycle generators and
multicircuit hydro units.
The G60 includes advanced automation and communication capabilities, extensive I/O options,
and powerful fault recording features that can simplify postmortem disturbance analysis and help
minimize generator downtime.

Key Benefits
• Secure, high-speed protection elements for complete generator protection, compliant with IEEE®
C37.102. extending asset life
• Available Ethernet Global Data (EGD) to ease integration with new and existing GE control systems
• Embedded Synchrophasor measurement capabilities (per IEEE® C37.118), eliminating the need for
dedicated PMUs and support for synchrophasor multi-cast (per IEC® 61850-90-5) reducing bandwidth
and communications infrastructure costs
• Advanced IEC 61850 Ed. 2 implementation, complete settings via SCL files and IEC 61850-9-2 process
bus solution enable resource and platform managing optimization and reduce cost of ownership
• Increased network availability via failover time reduced to zero through IEC® 62439-3 “PRP” support
• CyberSentry™ provides high-end cyber security aligned to industry standards and services (NERC®
CIP, AAA, Radius, RBAC, Syslog)
• Advanced fault and disturbance recording, including internal relay operating signals, eliminating the
need for external recording devices
Applications
• Medium to large generators typically driven by steam, gas, or hydraulic turbines
• Pumped storage generators used as pumping motors for reservoir storage
• Stand-alone protection or component in automated substation control systems
• Standard protection product offering on new GE generator installations
Protection and Control
As part of the UR family of Protection &Control devices, the G60 offers a high
degree of modularity in its design and functionality, providing superior performance
while meeting the toughest requirements of the marketplace.
Advanced protection and control features of this relay includes:
Generator Stator Differential
High-speed stator differential protection provides sub-cycle detection and high-speed
clearing of stator phase faults. Advanced CT saturation and failure detection algorithms
maintain immunity to high current AC and low current DC saturation conditions that may
occur due to external disturbances, such as transformer inrush or near generator faults,
without sacrificing speed or sensitivity.
100% Stator Ground 3rd Harmonic
100% stator ground fault protection is provided through a voltage differential feature that
responds to the unbalance of the third harmonic at the machine terminals and at the neutral
point. This method is insensitive to the absolute value of the third harmonic and is easily set
without the need for on-line measurements.
For generators with delta connected PTs, a third harmonic undervoltage element is also offered
for detecting a loss of the third harmonic voltage at the generator neutral.
Breaker Failure Protection
The breaker failure protection element monitors for timely operation of the connected breaker.
If a trip command is not successful in operating the breaker and clearing the fault, the breaker
failure element can be used to send trip signals to upstream breakers to clear the fault.