I/O Module to Termination Unit Cable Manufacturers ABB
Bailey Model(s) ABB Bailey Infi 90, ABB Bailey Infi 90 and Net 90
Additional Information I/O Module to Termination Unit Cable, NKTU11-09
Connects I/O Module to Termination Unit, 09 feet long, non-PVC
Estimated Shipping Size Dimensions: 15.0" x 3.0" x 14.0" (38.1 cm x 7.6 cm x 35.6 cm)
Weight: 1 lbs 10.1 oz (0.7kg )
Tariff Code: 8544429000
Country of Origin: United States Ships from Webster NY, USA
I/O Module to Termination Unit Cable
Specifically, HPC800 solutions:
− Use the extensive set of field-proven INFI 90 function code
algorithms as previous generation controllers
− Use traditional INFI-Net exception reporting over
redundant 100 Mbps Fast-Ethernet (PN800)
− Extend current Composer graphical design engineering
tools with device management capabilities
Further, Symphony Plus Rack and DIN control networks,
INFI-Net and PN800 respectively, can be connected via a
self-configuring INFI-Net to Ethernet bridge (IEB800) module.
Use of this bridge makes resident data on either network
available for use in control applications or display in the other
system.
Application areas of 086349-002 BB 41055 stepper linear control motherboard:
Distribution automation applications:
Automatic reclosing: A circuit breaker used for automatic reclosing tripping to handle instantaneous faults.
Automatic recovery: The 086349-002 BB 41055 stepper linear control motherboard isolates faults through a patented load transfer scheme and restores
Distribution capacitor control algorithm: more effectively utilize existing capacitor banks to achieve peak cycles.
Fault location: locate and isolate faults to reduce customer downtime.
Load and dead bus transmission: Monitor the substation network and transfer the load of overloaded transformers to other substations.
Load shedding/limiting: Provide intelligent load shedding conditions during overload.
Data recording/storage applications:
SOE local recorder: Record digital and analog SOEs to an external printer, PC, or CSV file.
Accumulator freeze: Coordinate the freeze of the accumulator group.
Event storage: Stores a historical record of the current value, status, and timestamp, and can store up to 7 days of simulation and accumulator data.
Historical simulation: stores the average historical value of 8 additional analog inputs.
MNS iS
1TGC910251 M0201 MNS iS Interface Manual Modbus, Release 7.0
1TGC910291 M0201 MNS iS Interface Manual PROFINET IO, Release 7.0
1TGC910281 M0201 MNS iS MControl Interface Manual Profibus Direct, Release 7.0
1TGC910261 M0201 MNS iS Interface Manual Redundancy, Release 7.0
1TGC910271 M0201 MNS iS MConnect Interface Manual, Release 7.0
1TGC910001 B0204 MNS iS System Guide
1TGC910201 M0201 MNS iS Quick Guide Installation and System Setup, Release 7.0
1TGC910090 M0201 MNavigate Help file V7.0
1TGC910018 M0208 MNS iS ATEX – Enhancements for Safety
1TGC910211 M0201 MNS iS Interface Manual MLink, Release 7.0
1TGC910111 M0201 MNS iS MLink Upgrade Kit Manual
1TGC910221 M0201 MNS iS Interface Manual Web Interface, Release 7.0
1TGC910241 M0201 MNS iS Interface Manual Profibus, Release 7.0