I/O Module to Termination Unit Cable Manufacturers ABB
Bailey Model(s) ABB Bailey Infi 90, ABB Bailey Infi 90 and Net 90
Additional Information I/O Module to Termination Unit Cable, NKTU11-10
Connects I/O Module to Termination Unit, 10 feet long, non-PVC
Estimated Shipping Size Dimensions: 15.0" x 3.0" x 14.0" (38.1 cm x 7.6 cm x 35.6 cm)
Weight: 1 lbs 10.1 oz (0.7kg ) I/O
Tariff Code: 8544429000
Country of Origin: United States Ships from Webster NY, USA
I/O Module to Termination Unit Cable
Specifically, HPC800 solutions:
− Use the extensive set of field-proven INFI 90 function code
algorithms as previous generation controllers
− Use traditional INFI-Net exception reporting over
redundant 100 Mbps Fast-Ethernet (PN800)
− Extend current Composer graphical design engineering
tools with device management capabilities
Further, Symphony Plus Rack and DIN control networks,
INFI-Net and PN800 respectively, can be connected via a
self-configuring INFI-Net to Ethernet bridge (IEB800) module.
Use of this bridge makes resident data on either network
available for use in control applications or display in the other
system.
Application areas of 086349-002 BB 41055 stepper linear control motherboard:
Distribution automation applications:
Automatic reclosing: A circuit breaker used for automatic reclosing tripping to handle instantaneous faults.
Automatic recovery: The 086349-002 BB 41055 stepper linear control motherboard isolates faults through a patented load transfer scheme and restores
Distribution capacitor control algorithm: more effectively utilize existing capacitor banks to achieve peak cycles.
Fault location: locate and isolate faults to reduce customer downtime.
Load and dead bus transmission: Monitor the substation network and transfer the load of overloaded transformers to other substations.
Load shedding/limiting: Provide intelligent load shedding conditions during overload.
Data recording/storage applications:
SOE local recorder: Record digital and analog SOEs to an external printer, PC, or CSV file.
Accumulator freeze: Coordinate the freeze of the accumulator group.
Event storage: Stores a historical record of the current value, status, and timestamp, and can store up to 7 days of simulation and accumulator data.
Historical simulation: stores the average historical value of 8 additional analog inputs.
Applications
The binary input board 23BE40 performs the following processing functions for different types of signals:
Digital filtering to suppress contact jumping
Suppression of technically induced chattering signals
Intermediate position suppression and double indication monitoring
Consistency check of all binary input channels assigned to digital measurement values
The 23BE40 has a buffer for temporarily storing 50 time-stamped event messages in chronological order, designated for transmission to the communication unit.
The board's microcontroller handles all time-critical tasks for the parameterized processing functions. In addition, it communicates interactively with the RTU560 system bus.
All configuration data and processing parameters are transmitted via the RTU560 system bus.
All configuration data and processing parameters are loaded from the communication unit via the RTU560 bus.
The board is equipped with a serial interface to the RTU560 system bus.
During initialization and operation, the board performs a series of tests. If a fault occurs, it is reported to the communication unit.
All fault conditions affecting the board's functionality are indicated as general fault signals by means of light emitting diodes (ST).
Faults in the board are detected by the communication unit.