The G62 and G72 Tricon System and Termination Enclosures provide
environmental protection and housing, with termination and marshalling
options for Triconex™ Tricon system chassis and modules and DIN rail
mounted Triconex termination devices, such as External Termination
Panels (ETPs), Field Terminations and External Termination Assemblies (ETAs).

FEATURES
The G62 and G72 Tricon system and termination enclosures offer the
following features:
• Available sizes:
• G62 enclosure - 800x800x2000mm
• G72 enclosure - 800x800x2200mm
• (Enclosure front) Vented enclosure
accommodates up to two Triconex™ Tricon system chassis
• (Enclosure rear) Two 1800 mm (or 2000 mm)
vertical DIN rails for mounting of Triconex termination devices to provide a total
of 3.6 m (or 4.0 m) of linear rail space. Optionally, one rail may be used to mount
terminal blocks for marshalling.
• Main power entry includes disconnect terminal blocks for 120/240 V ac or 125 V
dc systems, or 10 A, Type D, double pole circuit breakers for 120/240 Vac systems.
• Optional EMC/RFI line filters for redundant main power (Triconex recommended).
• Optional redundant 24 V dc field power - 480W (two field I/O power supplies) or
960W (four field I/O power supplies) with dedicated terminal block assemblies
providing independent disconnections for every Triconex termination device
• Vented enclosure for use in ordinary (IP 43) rated environments
• Option for EMC compliance
• Enclosure front and rear access, with optional safety glass front door
• Optional door intrusion monitoring switches
Alarm contact terminal block assembly for main chassis alarming, door intrusion
monitoring switches, enclosure temperature switch and field power supply status
• Compact design to minimize use of floor space with both front and rear access
that allow maximum density of enclosures in a control environment
• Available PVC or non-PVC wireways for field I/O cabling
• Generous 76 mm x 102 mm (3 in x 4 in) wire ducts with adequate capacity for
most wire management
• Bottom cable entry for field wiring
• Conveniently placed eyebolts for transporting and lifting the enclosures
• A 100 mm (4 in) plinth - total enclosure height of 2160 mm (85.0 in)
• Comfort handles with push-button/keylocks
• Three earth (ground) points; two protective earth (ground) studs, one isolated
protective earth (ground) rail and one isolated instrument earth (ground) rail
INTRODUCTION
The G62 and G72 enclosures are specifically designed for housing Tricon system
chassis and modules, DIN rail mounted Triconex termination devices and customer
-supplied terminal blocks for marshalling. These enclosures are available as vented
enclosures. They can be configured with:
• Up to two Tricon system chassis
• Two vertical DIN rails for mounting of Triconex termination devices. One rail may
be used to mount terminal blocks for marshalling.
The G62 and G72 enclosures are free-standing, floor mounted units with an IP 43
rating for location in mild (ordinary) environmental areas. Versions are available
with optional EMC compliance.
NOTE
In regions that require EMC compliance, you must order the EMC compliance option
if Tricon modules SMM or SRXM will be installed in a chassis in this enclosure.
Without these modules, these enclosures already fulfill the requirements for EMC
compliance.