General Technical Data
Ambient Temperature: 0...+25° C for site altitude up to 1000 m amsl (at rated values).
It is vital to consult our applications department for ambient temperatures
above 40° C and/or any enclosed environment.
Power De-rating:
(currents and torques)
1% / °C in range 40° C...50° C up to 1000 m amsl for site altitude above 1000 m amsl and 40° C
» 6% up to 2000 m amsl
» 17% up to 3000 m amsl
» 30% up to 4000 m amsl
» 55% up to 5000 m amsl
For site altitudes above 1000 m amsl, no de-rating with temperature reduction of 10° C / 1000 m
Temperature De-rating: If the application requires de-rating due to lower motor surface temperature,
please contact our applications department.
Ball-bearing Life: ≥ 20.000 operating hours
Phasing Diagram - All Motors
• When the motor is rotated C.W. (viewed from drive shaft end), the
following Bemf voltage waveforms result:
• Voltage phase-U, leads Voltage phase-V, by 120-degrees
• Voltage phase-V, leads Voltage phase-W, by 120-degrees
• Voltage phase-W, leads Voltage phase-U, by 120-degrees
Protection Class
Protection class IP69K has been created for high pressure and high temperature cleaning
according to DIN 40050-9. Code “6” (Dust tight. No ingress of dust.) defines the protection
against solids. Code “9K” (Protected against close-range high pressure, high temperature spray
downs.) defines the protection against liquids.
IP69K protection class is for static use only. This rating does not account for water present
while the shaft is rotating. For applications that require sealing during rotation, please contact
Kollmorgen Customer Support.