The power supplies can only be installed into slots PS1 (power supply #1) and PS2 (power supply #2). If
redundant power supplies are not needed, blanking plates must be installed in the slots not being used.
Branch circuit fuses, circuit breakers, and wiring must meet appropriate codes and authorities having
jurisdiction for the specific country (CE, UL, etc.). See Table 4-3 for maximum recommended fuse or
breaker ratings. Do not connect more than one main power supply to any one fuse or circuit breaker. Use
only the wire sizes specified in Table 4-3. which meet local code requirements.
Time delay fuses or circuit breakers must be used to prevent nuisance trips.

Power requirements depend on the number and type of modules supplied for each system. For a system
with a single I/O chassis, size the input power source according to the rating of the MicroNet Plus power
supply to which the source is connected. Do not size the supply mains for the sum of the MicroNet Plus
power supply ratings when redundant supplies are used. MicroNet Plus supplies are redundant when
installed in the same chassis. Redundant supplies share the load between them equally, but each must
provide for full load in the event that one of the units is disabled. Table 4-3 gives the maximum overload
protection for supply mains connected to any single or redundant pair of MicroNet Plus main power
supplies. It is not recommended that both MicroNet Plus main power supplies of a redundant pair be
connected to a single source, since failure of that source would disable the system.
Woodward STC (Steam Turbine Core) STCXT Core Software 10-027-206
Woodward PFC (Performance Control Core) PFC Core Software 10-028-721
Woodward LSC (Load Sharing Control) LSC Core Software 10-024-831
Moore SIEMENS Control Board 120 15763-201/13 15763-201-13 1576320113
SIEMENS MOORE QUADLOG BDM 16256-91 - QLBDMNBN
SIEMENS MOORE QUADLOG IDM 16107-103 - QLIDM115ACBBN
SIEMENS MOORE APACS + SDM+ - 39SDM048DCCBN
SIEMENS 15756-8-5 / 1575685
SIEMENS MOORE QUADLOG CDM - QLCDM048DCBAN
SIEMENS 6EQ1131-1AF00- 0BA0 CRITERION 900 RGI INPUT,MOORE 13935-12,13919 12,AE
SIEMENS MOORE 16436-1-03 SDM/CDM MARSHALLED TERMINATION MODULE
SIEMENS MOORE PROCESS CONTROL BOARD 352EA21NNF
SIEMENS MOORE INDUSTRIAL COMPUTER MODULE 16194-21/05 39ICM411NAN
SIEMENS 42H100 / 42H100
MOORE RTM 39RTMCAN / 16207-61R/10 RESISTANCE TEMPERATURE MODULE
Moore, Siemens A5E00282171/13 QLVIMBCN VIM Voltage Input Module