The EtherNet/IP communication modules:
• support messaging, produced/consumed tags, HMI, and distributed I/O.
• encapsulate messages within standard TCP/UDP/IP protocol.
• share a common application layer with ControlNet and DeviceNet.
• interface via RJ45. category 5. unshielded, twisted-pair cable.
• support half/full-duplex 10 Mbps or 100 Mbps operation.
• support standard switches.
• require no network scheduling.
• require no routing tables.

General
The power converter modules DCS800-S have the protection class IP00 and are to be mounted in a cubicle or finger protected area.
There are different sizes (D1. D2. D3. D4. D5. D6. D7), graduated in terms of current and voltage ranges.
All units are equipped with the DCS800 Control Panel.
It can be snapped into place on the power converter module or installed in the switchgear cubicle door by means of amounting kit.
Accessories such as external fuses, line reactors etc. are also available, to complete the drive system.
All converter modules up to 525 V and 1000 A (D1...D4) are equipped with field exciters.
The power section of the converters is available as single (2-Q) bridge or double (4-Q) bridge. 4-Q drives are required for regenerative breaking.
4-Q drives can be built by:
–Double (4-Q) armature bridge or –Single (2-Q) armature bridge plus a double (4-Q) field converter bridge
The bridge type has an influence on the maximum output voltage of the converter. See table below.
ATTENTION:
The installation of the drive must be planned such that all cutting, drilling,
tapping and welding can be accomplished with the drive removed from the enclosure.
The drive is of the open type construction and any metal debris must be kept from falling into the drive.
Metal debris or other foreign matter may become lodged in the drive circuitry resulting in component damage. !
An incorrectly applied or installed drive can result in component damage or a reduction in product life.
Wiring or application errors, such as, undersizing the motor, incorrect or inadequate AC supply,
or excessive ambient temperatures may result in malfunction of the system. !
Only qualified personnel familiar with DC drives and associated machinery should plan or implement the installation,
start-up and subsequent maintenance of the system.
Failure to comply may result in personal injury and/or equipment damage.
These faults and warnings can be cleared with a clear faults command.
You may have to perform a reset after power-up, or perform multiple resets.