Restrictions
• Volts per Hertz operation requires the use of the Custom User Defined Controller Communication Format.
If another Controller Communication Format is selected (e.g. Velocity Control,
Position Control or User Defined Control) and the drive is configured for Volts per Hertz operation,
the Drive Module will not connect to the controller.
• This module sometimes experiences PMI Comm faults during power cycles.
For example, when the Drive Module and PMI processor are power-cycled the drive module initializes its interface
with the PMI processor. During the transition from initialization to synchronized communication,
the Drive Module sometimes experiences communication faults and warnings.

General
The power converter modules DCS800-S have the protection class IP00 and are to be mounted in a cubicle or finger protected area.
There are different sizes (D1. D2. D3. D4. D5. D6. D7), graduated in terms of current and voltage ranges.
All units are equipped with the DCS800 Control Panel.
It can be snapped into place on the power converter module or installed in the switchgear cubicle door by means of amounting kit.
Accessories such as external fuses, line reactors etc. are also available, to complete the drive system.
All converter modules up to 525 V and 1000 A (D1...D4) are equipped with field exciters.
The power section of the converters is available as single (2-Q) bridge or double (4-Q) bridge. 4-Q drives are required for regenerative breaking.
4-Q drives can be built by:
–Double (4-Q) armature bridge or –Single (2-Q) armature bridge plus a double (4-Q) field converter bridge
The bridge type has an influence on the maximum output voltage of the converter. See table below.
ATTENTION:
Energized industrial control equipment can be hazardous.
Severe injury or death can result from electrical shock, burn, or unintended actuation of controlled equipment.
Hazardous voltages may exist in the cabinet even with the circuit breaker in the off position.
Recommended practice is to disconnect and lock out control equipment from power sources,
and discharge stored energy in capacitors, if present.
If it is necessary to work in the vicinity of energized equipment, the Safety Related Practices of NFPA 70E,
“ELECTRICAL SAFETY FOR EMPLOYEE WORKPLACES” must be followed.
DO NOT work alone on energized equipment!
These faults and warnings can be cleared with a clear faults command.
You may have to perform a reset after power-up, or perform multiple resets.