Heat/Cool Minimum On-times
Words 6 and 8 for channel 1
These values determine the minimum cycle time after which loop
TPO bits will turn ON. They are used to allow contactors time to close
or pull in. If the contactor is energized for less than this value, the
contactor will not close, but the attempt will count as a cycle.
For example, suppose you set the TPO period for 10 seconds and the
minimum ON time to 1 second. Then if the module calculates a CV%
of 10% or less, the TPO bit for that zone will not turn ON.

Universal Remote I/O (RIO) Network
The strength and versatility of the Universal Remote I/O network comes from the breadth of products it supports.
In addition to 1746 I/O, the Universal Remote I/O network supports many Allen-Bradley and third-party devices.
Typical applications range from simple I/O links with controllers and I/O, to links with a wide variety of other types of devices.
You connect devices through remote I/O adapter modules or built-in remote I/O adapters.
Using the Universal RIO Network instead of direct-wiring a device over a long distance to a local I/O chassis reduces installation,
tart-up, and maintenance costs by placing the I/O closer to the sensors and actuators.
SLC 5/03, 5/04, and 5/05 processors support pass-thru which lets you configure RIO devices remotely from an Ethernet,
DH+, or DH-485/DF1 network, as well as block transfer instructions for faster reading and writing of I/O data.
WOODHEAD SST DHP-PCI V1.2.0 SD-PCI-U DATA HIGHWAY PLUS INTERFACE CARD
Molex SST-PB3-VME-2 Brad Communication Board SSTPB3VME2E
SST Woodhead SST-ESR2-CLX-RLL Ethernet Modbus/Serial Modbus Communication
Woodhead PB3-PCIe 2 SST-PB3-PCIE 1 V1.1.0 Communication card
MOLEX SST-DN4-PCIE-H / SSTDN4PCIEH
SST 5136-PFB-PCI Profibus Communications Adapter Module
AMAT 0190-34511 REV. 08 SST woodhead DNet bus scanner DNPCPCI3U1-NC- 3V V1.3.4
WOODHEAD SST-DN3-PCU-1 DEVICENET INTERFACE CARD
SST / WOODHEAD 5136-PFB-VME PROFIBUS INTERFACE CARD 5136PFBVME NIB
WOODHEAD SST-DN3-PCU-2( E) PCI DEVICENET INTERFACE CARD DN3-PCU-2(E) V1.2.8
Brad Communications / Fanuc / Woodhead. SST-PFB3-VME-1 -E