Introduction
The DeltaV SIS™ process safety system has a uniquely scalable modular architecture that is based on the CHARMs
Smart Logic Solver (CSLS) and the unprecedented flexibility and ease of use of the Emerson Electronic Marshalling solution.
Each CSLS provides I/O processing, Safety Integrity Level 3-capable logic solving, and diagnostics in a single logic solver.
The CSLS supports up to 96 local individually configurable channels, allowing flexibility for implementing safety
instrumented functions and is designed specifically for multi-core home run cables or field junction box installation.
All communications are completely redundant from the channel (LS CHARM) to the CSLS. Integrated HART® I/O
brings field diagnostics into the CSLS.
Specifications
DST Limit 1500
SCADA Tags 3200
Max Data Values Sent 4000/second
Max Data Values Received 500/second
Max Unsolicited Client Nodes 120
Module Execution Rates 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 30s, 60s
User Memory 96 MB
Fuse Protection (Internal) 3.0 A, non-replaceable fuses
Power Dissipation 5.0 W typical, 7.0 W maximum
Operating Temperature -40 to 60 °C (-40 to 140 °F)
Storage Temperature -40 to 85 °C (-40 to 185 °F)
Reltive Humidity 5 to 95% , non-condensing
Shock 10 g½-sine wave for 11 ms
Vibration 1mm Peak-to-Peak from 2 to 13.2 Hz, 0.7g from 13.2 to 150 Hz
PK Flex Controller
The DeltaV PK Flex Controller builds upon the ground breaking innovation and technology of the PK Controller.
It provides the same powerful functionality but with the added advantage of flexible capacity and a subscription
based license that will help reduce capital costs.
The DeltaV PK Flex Controller is configured like any other controller in a DeltaV system and can be installed as simplex
or redundant node. It can be used for applications in a wide variety of sizes, from 50 to 1500 Flex DSTs, depending on
which capacity customers subscribe to. For Ethernet-APL Device Control,
the DeltaV PK Flex Controller can be used for a variety of Ethernet-APL Devices, supporting Modbus
TCP client or EtherNet/ IP interface in port P01 and PROFINET(PN1).
P01 and PROFINET (PN1) can be enabled at the same time for greater functionality
Benefits
Optimized process reliability: Emerson has extended DeltaV Electronic Marshalling technology to safety instrumented systems,
with DeltaV SIS being a key component of the Smart SIS Solution.
Research shows that more than 90% of all faults in SIS applications occur in field instruments and final elements.
The DeltaV SIS process safety system has the world’s first Smart Logic Solver using LS CHARMs.
It communicates with intelligent field devices using the HART protocol to diagnose faults before they cause spurious trips.
This approach increases process availability and reduces lifecycle costs.
Flexibility to meet project needs: Whether you have an isolated wellhead or a large emergency shutdown
(ESD) application, the DeltaV SIS system scales to provide you with the safety coverage you need for your SIL 1, 2,and 3 safety functions.
Each CHARMs Smart Logic Solver provides I/O processing, SIL 3-capable logic solving, and diagnostics.
This means that processing power is added as the system expands.
If the I/O limit is reached, a CSLS is added increasing memory and processing capacity along the additional I/O.
This allows for I/O scalability without impacting the scan rate.
Modularity also provides isolation of safety instrumented functions (SIF).
This isolation eliminates single-points of failure for improved availability and safety integrity.
DeltaV SIS components can be added online to facilitate system expansions.
Recommended Products P/N:
Emerson SE4023 Virtual I/O Modules | Emerson DeltaV KJ2201X1-BA1 SIS Logic Solver (SLS 1508) |
Emerson SE3007 KJ2005X1-BK1 12P4688X042 advanced industrial input/output module | Emerson DeltaV KJ2201X1-HA1 Simplex SLS Terminal Block |
Emerson DeltaV KJ1501X1-BA2 System Power Supply(AC/DC) | Emerson DeltaV KJ2201X1-JA1 SLS Redundant Terminal Block |
Emerson DeltaV KJ1501X1-BB1 System Passthrough Power Supply 12/12VDC(DC/DC) | Emerson DeltaV KJ2221X1-BA1 SISNet Repeater |
Emerson DeltaV KJ1501X1-BC1 System Dual DC Power Supply (DC/DC) | Emerson DeltaV KJ2221X1-EA1 SIS Net Repeater Carrier |
Emerson DeltaV KJ1501X1-BC2 System Dual DC Power Supply 24/12VDC(DC/DC) | Emerson DeltaV KJ2222X1-BA1 SISNet Distance Extender |
Emerson DeltaV KJ1501X1-BC3 System Dual DC Power Supply(DC/DC) | Emerson DeltaV KJ2231X1-BA1 Auxiliary Relay ETA-Direct Module |
Emerson DeltaV KJ1501X1-BK1 Controller | Emerson DeltaV KJ2231X1-BB1 Auxiliary Relay DTA-Direct Module |
Emerson DeltaV KJ1502X1-BA2 BULK AC TO 24 VDC POWER SUPPLY | Emerson DeltaV KJ2231X1-BC1 Auxiliary Relay Diode Module |
Emerson DeltaV KJ1611X1-EF1 Controller MODULE | Emerson DeltaV KJ2231X1-EA1 SIS Relay Module |
Emerson DeltaV KJ1700X1-BA1 Media Converter | Emerson DeltaV KJ2231X1-EB1 Voltage Monitor |
Emerson DeltaV KJ1710X1-BA1 Single Port Fiber Switch | Emerson DeltaV KJ2231X1-EC1 End of Line Resistance Module |
Emerson DeltaV KJ1740X1-BA1 Four Port Fiber Switch | Emerson DeltaV KJ2231X1-ED1 RC Compensator |
Emerson DeltaV KJ2001X1-BA1 CHARMs Smart Logic Solver | Emerson DeltaV KJ2231X1-EE1 SIS Current Limiter |
Emerson DeltaV KJ2002X1-BA1 M3 Controller | Emerson DeltaV KJ4001X1-CA1 I/O Terminal Block |
Emerson DeltaV KJ2002X1-CA1 M5+ Controller | Emerson DeltaV KJ3201X1-BA1 DI CARD 24V DRY CONTACT SERIES 2 |
Emerson DeltaV KJ2003X1-BA2 MD Controller | Emerson DeltaV KJ2005X1-BA1 MX Controller |
Emerson DeltaV KJ2003X1-BB1 MD Plus Controller | Emerson DeltaV KJ2101X1-BA1 PROVOX M3+ CONT CAR |
Emerson DeltaV KJ2004X1-BA1 Remote Interface Unit | Emerson DeltaV KL2101X1-BA1 CHARM I/O Card (CIOC) |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved