Refer to the Series 90-30 Programmable Controller Installation Manual, GFK-0356 for details on
power supplies and module load requirements.
The bottom LED, User Supply OK, indicates that the user provided 24V supply is within
specifications, thereby enabling the analog side of the module to work properly
This exceptional control solution is compact, cost-effective, and adaptable, serving as a compact PLC, distributed
I/O, or distributed control system.
The 16-Channel Analog Current Input module provides up to 16 single-ended input channels,
each capable of converting an analog input signal to a digital value for use as required by your application.
References Used
The number of 16-Channel Analog Current Input modules which may be installed in a system
depends on the amount of %AI and %I references available. Each module uses 1 to 16 %AI
references (depending on the number of channels enabled) and from 8 to 40 %I (depending on
alarm status configuration) references.
Configuring IC693ALG223 Using Hand-Held Programmer
You can also configure the 16-Channel Analog Current Input module using the Series 90-30
Hand-Held Programmer. In addition to the information in this section, refer to GFK-0402, the
Hand-Held Programmer for Series 90-30/20/Micro Programmable Controllers User’s Manual
for more information on configuration of Intelligent I/O modules.
Although you can change the number of actively scanned channels with the Logicmaster
90-30/20/Micro configurator function, the Hand-Held Programmer does not support editing the
number of actively scanned channels. If the 16-Channel Analog Input module is initialized by
a Hand-Held Programmer, the number of actively scanned channels is 16.
If a module had been previously configured with Logicmaster 90-30/20/Micro software and the
number of actively scanned channels has been changed from 16, that number will be displayed
on the bottom line of the Hand-Held Programmer display following the AI. You can edit data
with the Hand-Held Programmer only for the active channels, but can not change the number of
actively scanned channels.
The maximum number of 16-Channel Analog Current Input modules which may be installed in a
system are:
4 in a Model 311, Model 313, and Model 323 system
8 in a Model 331 system
12 in a Model 340 and Model 341 system
51 in a Model 351 and Model 352 system
When planning the module configuration for your application you must also consider the load
capacity of the installed power supply and the total load requirements of all modules that are
installed in the baseplate.
We have the same series of models in stock.
If you don't find the model you need, please contact us and we will provide you with an official quotation!
GE IC800SSI104D2-CE VersaMotion S2K controller
GE IC800SSI104P2-CE S2K Series Standalone Motion Controller
GE IC800SSD107RS1-CC VersaMotion S2K controller
GE IC800SSI107RS1-CE S2K Series Standalone Motion Controller
GE IC800SSI107RD2-CE VersaMotion S2K controller
GE IC800SSD104RS1-CC S2K Series Standalone Motion Controller
GE IC800SSI104RS1-CE VersaMotion S2K controller
GE IC800SSI104RD2-CE S2K Series Standalone Motion Controller
GE IC800SSI107RP2-CE VersaMotion S2K controller
GE IC800SSD216S1-EC S2K Series Standalone Motion Controller
GE IC800SSI216D2-EE VersaMotion S2K controller
GE IC800SSI107D2-CE S2K Series Standalone Motion Controller
GE IC800SSI107P2- CE VersaMotion S2K controller
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved