Product Features & Benefits
• Immediate protection response to extreme voltage conditions
with instantaneous functions.
• Timings can be tailored to the application with individually
adjustable definite, short inverse, medium inverse, or long inverse
timing for each time-delayed under/overvoltage function.
• Flexible pickup is continually adjustable over a wide range.
• Minimized PT costs as a result of low sensing burden.
• Reduced battery load with low burden power supply.
• Accurate, repeatable, and reliable operation.
• Simple HMI provides clear and intuitive settings for easy configuration.
• LED targets provide clear annunciation of status.
• Easily perform in-case system and device tests using test paddles.

The BE3-25 series are synchronizing check relays, also known
as paralleling relays. They are used to ensure that two AC
supplies are synchronized. For a system to be synchronized,
the frequency, phase angle, and voltage must be within preset
limits. The BE3-25-****4 can monitor either utility mains bus
bar and incoming generator, or two generators.
The BE3-25-****4 offers user adjustment of the reset voltage
from 10 to 30%. This voltage corresponds to 6 to 20 electrical
degrees. The unit compares the input voltage and phase
relationship of the bus bar to that of the generator.
When the signal is within the preset limits, the relay energizes.
The BE3-25-****5 operates as the BE3 25-****4.
but has the additional feature of a dead bus facility.
This enables the relay to energize with a generator supply
only, which is a common requirement when utility mains failure
occurs.
The Electronic Manual Voltage Control MVC-300 is a solid-state device en
closed by a wrap-around metal chassis. The MVC-300 is for mounting through
a panel with controls accessible from the front of the panel or can be mounted
behind the panel. A terminal strip located on the rear of the device facilitates
installation. A manual voltage adjust potentiometer and a manual-off-auto
switch are provided on the front face of the unit. For use of a user-supplied
external manual adjust potentiometer or for adjust by a motor operated control
(MOC), order MVC-301. The MVC-300 and MVC-301 are designed to operate
with Basler voltage regulators powered from 120 or 240 volt AC sources up to
320 Hz. The adjustable output of the MVC-300 supplies power to 32. 63 or 125
volt fields at 7 amps.
Basler Electric offers a high powered, low-cost digital excitation control system,
the DECS-100. This environmentally rugged product is ideally suited for
controlling the output of brushless excited synchronous generators up to 5MW.
These relays provide a reliable response to protect power system
equipment from adverse voltage conditions.
| Basler Electric BE1-25 M9FA6PN4N0F / BE125M9FA6PN4N0F |
| Basler Electric BE1-50/51B-235 / BE15051B235 Self-Powered Time Overcurrent Relay |
| Basler Electric PLA2400-12GM / PLA240012GM |
| Basler Electric DECS 125-15-B2C5 DIGITAL EXCITATION CONTROL SYSTEM |
| Basler Electric BE1-851 Overcurrent Relay H5A2S1N |
| Basler Electric BE1-59N A6EE1JC0N1F Ground Fault Overvoltage Relay |
| Basler Electric BE3-25-1S1N4 / BE3251S1N4 Synchronizing Check Relays |
| Basler Electric L304KC / L304KC Camera Interface |
| Basler Electric SCA1300-32FC / SCA130032FC |
| Basler Electric BE1-27 A3EE1JA1N6F Voltage Relay |
| Basler Electric BE1-51 G1EZ1PA1N0FY Time Overcurrent Relay |
| Basler Electric 9073800-103 Power Supply 110/120v-ac 12.8a Amp 15v-dc |
| Basler Electric Relay BE1-50/51B-207 Overcurrent Relay |
| Basler Electric BE1-51-H5EZ2PB1N0F / BE151H5EZ2PB1N0F Time Overcurrent Relay |
| Basler Electric BE1-32-A1E-E1C-B0N0F / BE132A1EE1CB0N0F |
| Basler Electric BE1-81O/U T3ED1JB7N0F (AS PICTURED) NSNP |
| Basler Electric DGC-2020 Digital Genset Controller 100-480v-ac |
| Basler Electric SSR 63-12 Static Voltage Regulator 63VDC 100-139 VAC |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2026 Cld , All Rights Reserved K-JIANG All rights reserved