• Designed to interface with the M-7679 R-PAC.

• Allows the M-7679 R-PAC to monitor third party external power supplies and

12/24 V battery chargers.

• Provides four 0-30 Vdc Analog inputs. Using S-7600 IPScom communications

software, these inputs can be monitored and configured with two level

alarm settings per channel, and used in IPSlogic custom configurations.

• Monitor and test the battery system. Turns off the battery supply to enter

sleep mode during power loss.

• Transient and reverse polarity protected

• Operates on DC power from 8 to 30 V

• Substation hardened -40° C to +85° C

• Conformal coated

Introduction

The M‑2035 Interface Module monitors power supplies and battery chargers

used in Reclosers that have been retrofitted to operate with Beckwith

Electric's M-7679 R-PAC system. This analog to digital interface measures

voltage, current, and current direction which can be monitored with the

same S-7600 IPScom communication software used with the recloser control.

The interface module can be DIN rail mounted during installation of the

M-7679 R-PAC and includes a SATA cable for easy hookup to the Aux I/O port

in the recloser control. The module will accept 8 to 30 Vdc power from the

existing power supply and batteries.

The module features essential indicator lights for battery and communication

status plus on‑board and remote manual wake-up pushbuttons to restore

function after a power failure. Four extra analog to digital inputs are available

for voltage measurements up to 30 Vdc. The module is able to periodically

test the batteries by briefly disconnecting the charger with a high side switch

and switching on a resistive load for five seconds.

Configurable DC Power Monitoring

Four analog inputs allow the user to remotely monitor DC voltages from 0 to

30 Vdc. Each input can be configured with two setpoints to report when voltage

drops below the specified levels. The analog to digital converter is 12 bit and

averaging is done over 128 samples to increase resolution to 16 bits.

Analog metering data is updated every 64 ms.

Summary of Operation

• Installed between the battery and battery charger (with fuse protection for

reverse polarity of charger or battery), the M-2035 measures battery voltage,

charge and discharge current, detects AC power loss, and sends the

measurements to the controller through the SATA communication interface.

• Continuously monitors charger voltage. Conducts scheduled battery load

tests on 12 and 24 V battery configurations while automatically disconnecting

and reconnecting the battery charger.

• During tests, module controls the battery load resistor via command from

the M-7679 R-PAC so that when the load resistor is turned on, it disconnects

the high side switch. Reconnects high side switch after load resistor is turned

off. Does not turn on load resistor if loss of main power is detected.

• When running on battery power, the M-7679 R-PAC commands the M-2035

module to enter low power mode if the battery voltage drops below "Vmin Bat"

setting, disconnecting the M-7679. Local or remote pushbutton provides "

wakeup from sleep" functionality. When pressed, the pushbutton releases

module from sleep and activates high side switch to reconnect the battery

and power supply.

• While in the sleep mode, the M-2035 module wakes up every 5 seconds to

measure voltage at Charger Input (TB4) to determine when main power

returns. Provides "wakeup" functionality when main power is restored.

Turn-on/off Battery Load Test Command

Test frequency is user defined in the Battery Charger common setpoints in

IPScom communication software.

The M-7679 R-PAC issues the "Turn-on/off Battery Load Test" command to the

M-2035 to test the battery capacity only when the charger is operating from

the main power supply.

Battery Supply Off Command

When the battery voltage decreases to less than "Vmin Batt" (Figure 1) the

battery supply to the M-7679 R-PAC will be turned off to protect the battery.

The M-2035 remains connected to the battery. Discharging 

  • Beckwith Electric M-3410A Intertie/Generator Protection Relay
  • Beckwith Electric B-1612 Adapter
  • Beckwith Electric B-1652 Adapter
  • Beckwith Electric B-1685 Adapter
  • Beckwith Electric M-2035 Analog to Digital Interface Module
  • Beckwith Electric B-2291 Digital Input Guard
  • Beckwith Electric M-2406 Recloser Control Adapter Chassis
  • Beckwith Electric M-3908 Universal Contact Input Adapter
  • Beckwith Electric M-3801D IPS Plot Software
  • Beckwith Electric M-7651A D-PAC
  • Beckwith Electric M-2979 Recloser Control Cabinet
  • Beckwith Electric M-0359 SYNCROCLOSER MOD512
  • Beckwith Electric M-2001C-6ELFA Tap Changer Controller Voltage Regulator Control
  • Beckwith Electric M-0124 TERMINAL BOARD ADAPTER PLATE 13 POS
  • Beckwith Pride M-0296C 3ph Programmable Relay
  • Beckwith Electric M-0388 Syncrocloser Check Relay
  • M-0170A AC Current Relay Beckwith Electric
  • Beckwith Electric Intertie Protection M-3520 Instruction Manual
  • M-3311 M-3311 7113 BECKWITH ELECTRIC TRANSFORMER PROTECTION RELAY
  • Pride M-0296b 3 phase Programmable Relay Beckwith Electric Co
  • Beckwith Electric M3310 Integrated Transformer Protection Panel
  • Beckwith M-0145 First Customer Protector
  • Beckwith Electric M-0296C 3 phase Programmabel Relay
  • Beckwith Electric M-0389 VOLTAGE VERIFIER
  • M-3425 M-3425-A1DE BECKWITH ELECTRIC GENERATOR PROTECTION RELAY SL
  • Beckwith Electric M-0420 Multifunction Relay Protection Module 48VDC
  • M-3430 M-3430M0D515 BECKWITH ELECTRIC GENERATOR PROTECTION RELAY
  • Beckwith Electric Tapchanger Control M-0067E
  • Beckwith M-2001D-6L4S20C0S0X Tap Changer Control Surplus
  • BECKWITH ELECTRIC M3425A-STD1 Generator Protection 85-280VDC
  • Beckwith Electric High Speed Sync-Check Relay #M-0245C Mod #22 (NIB)
  • Beckwith Electric M-7679 R-PAC
  • Beckwith Electric TAPCHANGER CONTROL M-2001C-6SL
  • Beckwith P-2216 Generator Protection Power Main Board 450-00258 B-1038
  • Beckwith Electric P-2216 Generator Protection Power Main Board 450-00258 B-1038
  • Beckwith Electric M-2293 Tap Changer Control
  • Beckwith Electric M-4272-6AB1EH0 Integrated Synchronizing System Motor Bus Transfer
  • Beckwith Electric TapChanger Control M-2001B Series M-2001B-C2 Surplus
  • Beckwith Electric P-1939 Generator Protection Relay Annunciator Panel B-0898 Rev A-2
  • Beckwith Electric M-3311A 8 Output D-0179 60-140 VAC Transformer Protection
  • Beckwith Electric B-2355 Adapter Kit
  • Beckwith Electric B-2203 Adapter Kit
  • Beckwith Electric B-2271 Adapter Kit
  • Beckwith Electric B-2293 Adapter Kit
  • Beckwith Electric B-6200A-U1 Hinge Kit
  • Beckwith Electric M-2032B Battery Charger/Power Supply
  • Beckwith Electric M-2900A Tapchanger Control Cabinet
  • Beckwith Electric M-6200A Digital Voltage Regulator Control
  • Beckwith Electric M-0124 Surface Mounting Adapter
  • Beckwith Electric B-2048 Resistor Assembly
  • Beckwith Electric M0169A Auxiliary Current Transformer Units
  • Beckwith Electric M-0121 and M0169A Auxiliary Current Transformer Units
  • Beckwith Electric M-0404 Voltage Isolation Transformer
  • Beckwith Electric M-0329B LTC Backup Control
  • Beckwith Electric M-0001 Battery Transient Suppressor
  • Beckwith Electric Module d’Équilibrage en Parallèle M-0115A
  • Beckwith Electric M-0115A Parallel Balancing Module
  • Beckwith Electric M-2025D Current Loop Interface Module
  • Beckwith Electric M-0362 Voltage Isolation Transformer
  • Beckwith Electric M-2025B Current Loop Interface Module
  • Beckwith Electric M-2174B Adapter Panel
  • Beckwith Electric M-2027 AC to DC Backup Power Supply
  • Beckwith Electric M-2054 Surface Mount Kit
  • Beckwith Electric M-2067B Adapter Panel
  • Beckwith Electric M-2270B Adapter Panel
  • Beckwith Electric M-2050 Surface Mounting Kit
  • Beckwith Electric M-2230 Adapter Panel
  • Beckwith Electric M-2052 Connection Harness
  • Beckwith Electric M-2051 Connection Harness
  • Beckwith Electric M-2279D Adapter Panel
  • Beckwith Electric M-2053 Adapter Panel
  • Beckwith Electric M-2339 Adapter Panel
  • Beckwith Electric M-2948 Tap Position Sensor
  • Beckwith Electric M-3425A Comprehensive Generator Relay
  • Beckwith Electric M-0193B Syncrocloser® Unit
  • BECKWITH ELECTRIC M-3425A Generator Prothection
  • Beckwith M-3425 Integrated Generator Protection
  • GE XAMP-1-1-2-0-0 XAMP Preamplifer
  • Honeywell 8-Node Enhanced Micro TDC 3000
  • Beckhoff ELM3142-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3104-0030 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3104-0020 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3104-0000 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3102-0120 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3102-0100 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3102-0030 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3102-0000 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3004-0030 | EtherCAT Terminal, 4-channel analog input, voltage
  • Beckhoff ELM3004-0000 | EtherCAT Terminal, 4-channel analog input, voltage
  • Beckhoff ELM3002-0425 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0405 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0325 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0305 | EtherCAT Terminal, 2-channel analog input, voltage
  • Basler Electric SBO222 Excitation Support System
  • Basler Electric SBO221 Excitation Support System
  • Basler Electric 9488800100 AVC Sensing Module
  • Basler Electric 36T865-2 BE03752001
  • Basler Electric BE1-25 BE1-25/79TR CONTROL SYNC-CHECK RECLOSING RELAY
  • Basler Electric M-300 149D940G02 POWER SUPPLY T159095
  • Basler Electric PCB CONTROL BOARD 9261402111 9346000033 S050105
  • Basler Electric BE 28053-002 Transformer BE28053002
  • Basler Electric BE3-GPR GENERATOR PROTECTIVE RELAY
  • Basler Electric VAR POWER FACTOR CONTROLLER MODEL SCP-250-G-60 P/N 9 1100 00 109
  • Basler Electric BE3-32-1S1N1 Reverse Power Relay - 277v, 5A
  • Basler Electric BE03303001 VOLTAGE TRANSFORMER
  • Basler Electric BE3-GPR-P1BVSF GENERATOR PROTECTIVE RELAY
  • Basler Electric BE1-60 VOLTAGE BALANCE RELAY T176884
  • Basler Electric 9022900-103 6-7VA 60HZ
  • Basler Electric BE1-59-A4E-E1K-B1S3F / BE159A4EE1KB1S3F Over Voltage Relay
  • Basler Electric KR2FF-M Voltage Regulator 9 1163 00 103
  • Basler Electric BE1-81-O/UT3ED1JB6N0F / BE181OUT3ED1JB6N0F
  • Basler Electric PCB Assembly 9059701100 919620
  • Basler Electric SR8A2B01A3E Static Voltace Regulator
  • Basler Electric SSR 63-12 STATIC VOLTAGE REGULATOR 600VAC 50/60HZ 9 1859 00 101
  • Basler Electric Solid State Protective Relay BE1-60
  • Basler Electric BE3-47N/27-3A4N2 9320400101 120V Phase Balance Relay
  • Automatic Voltage Regulators DECS100-B15 For Basler Electric Generator
  • Basler Electric BE1-25/ BE1-25M1GA6PN4R3F STOCK G277 Sync Check Solid State Protective Relay
  • Basler Electric BE25927001 Current Transformer
  • Basler Electric 1783 Be1783 Contactor Dc Current Transformer Coil, 1200:5A Ratio
  • Beckhoff ELM3002-0235 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0225 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0205 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0030 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0000 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff EL3783-0100 | EtherCAT Terminal, 3-channel analog input, multi-function
  • Beckhoff EL3783 | EtherCAT Terminal, 3-channel analog input, multi-function
  • Beckhoff EL3773 | EtherCAT Terminal, 3-channel analog input, multi-function