• For Transformers of All Sizes:
• Two-, Three- or Four-winding Transformers for Transmission and
Distribution applications
• Generator-Transformer Unit Overall Differential
• Unit Protection of Other Electrical Apparatus and
certain Bus Arrangements (including those with a transformer in
the zone)
• Additional Applications: System Backup Protection, Load Shedding
(voltage and frequency), Bus Protection, and individual Breaker
Failure Protection for each winding input
• Available voltage configurations include zero, two or four voltage inputs
• Ground Differential configurations include one, two or three current
inputs
• Optional Ethernet Connection and Expanded I/O
• Optional Voltage Package includes, 24 Volts/Hz Overexcitation, 27
Phase Undervoltage, 59G Ground Overvoltage and 81O/U Over/Under
Frequency

Standard Protective Functions
• Negative-sequence inverse time overcurrent (46)
• Winding thermal protection (49)
• Four-winding instantaneous phase overcurrent (50)
• Breaker Failure (50BF)
• Instantaneous ground overcurrent (50G)
• Instantaneous residual overcurrent (50N)
• Four-winding inverse time phase overcurrent (51)
• Inverse time ground overcurrent (51G)
• Inverse time residual overcurrent (51N)
• Two, three or four-winding phase differential (87T) and high set
instantaneous (87H)
• Ground differential (87GD)
• IPSlogic®
Optional Voltage Protection Package
• Overexcitation (24) V/Hz, two definite time and one inverse time
elements
• Phase Undervoltage (27) function for load shedding
• Phase Overvoltage (59)
• Ground Overvoltage (59G)
• Over/Underfrequency (81O/U)
Standard Features
• Target Module
• Human-Machine Interface (HMI) Module
• Eight programmable outputs and six programmable inputs
• Oscillographic recording
• Through-Fault Monitoring
• 8-target storage
• Real time metering of measured and calculated parameters,
including demand currents
• Two RS-232 and one RS-485 communications ports
• Standard 19" rack-mount design
• Removable printed circuit board and power supply
• 50 and 60 Hz models available
• 1 or 5 A rated CT inputs available
• S-3300 IPScom® Communications Software
• IRIG-B time synchronization
• Sequence of Events Log
• Breaker Monitoring
• Multiple Setpoint Groups
• Trip Circuit Monitoring
• Includes MODBUS and DNP 3.0 protocols
• Summing Currents from multiple sources for 49. 50. 51. 50N,
51N, 87 GD and Through Fault functions
Optional Features
• Redundant Power Supply
• Ethernet Port RJ-45 10/100 Base-T (MODBUS over TCP/IP)
• Ethernet Port RJ-45 10/100 Base-T (DNP over TCP/IP)
• Serial Port TIA-232 with RJ-45 Connector (DNP)
• Serial Port TIA-485 with RJ-45 Connector (DNP)
• Ethernet Port RJ-45 10/100 Base-T (IEC 61850 Protocol)
• M-3801D IPSplot® Plus Oscillograph Analysis Software
• Expanded I/O (8 additional outputs and 12 additional inputs)
• Standard and Expanded I/O Models available in vertical panel mount
• Close Circuit Monitoring on Expanded I/O units