From:Beckwith Electric | author:Mr.Chen | Time :2026-09-04 | 20 view: | 🔊 Click to read aloud ❚❚ | Share:

• Provides 24 Vdc power to any Beckwith Electric M-7600 Series

Protection System or Control configured with Low Voltage power supply

• Provides 13.8 Vdc Accessory power

• Accepts AC or DC power input from 105 to 285 Vac (50/60 Hz) or 120

to 285 Vdc

• Charges a 24 Vdc battery system which upon AC power interruption

can be used as temporary power (UPS) supply

• Transient protected

• Substation hardened -40° C to +85° C

• Conformal coated

Introduction

The M‑2032B Battery Charger/Power Supply provides 24 Vdc output to power

the low voltage configured M‑7600 series of Beckwith Electric Protection and

Control Systems. Also provided is a 13.8 Vdc output which can be used to

power radios or other auxiliary equipment.

In addition to providing output power, the M‑2032B is capable of charging 24

Vdc batteries when main power is supplied. Included is circuitry to detect a

loss of main power and automatically provide backup power from the 24 Vdc

batteries ensuring operation is not interrupted.

Stand Alone Applications

In a stand alone application the M‑2032B is designed to provide the following

features:

• 24 Vdc Output

• 13.8 Vdc Output

• 24 Vdc Battery Charging

• Circuitry to detect a loss of main power and automatically provide backup power

from the 24 Vdc batteries ensuring operation is not interrupted.

• When running on the 24 Vdc batteries the M‑2032B will shut down if the battery

voltage drops below 19 Vdc.

The M‑2032B is intended for indoor use or mounted inside a chassis or enclosure

only.

Battery Charging Features

The M‑2032B is designed to charge a 24 V sealed lead‑acid battery. It includes an

internal circuit to prevent overcharging of the batteries and extend their life.

• Tri‑Level Bulk/Absorption/Float Charger with Pre‑Charge

• When battery voltage is below 21 Vdc the charge current is limited to 40 mAdc

(Pre‑Charge), once the battery voltage is greater than 21 Vdc, the charger will begin

charging at the higher rates (Bulk/ Absorption/Float).

This prevents high current in a damaged battery. The Bulk mode charges the battery

at a rate that minimizes charge time and maximizes battery capacity. The Float mode

maintains the battery charge after the Bulk mode charge has finished, preventing

overcharging of the battery.

• The battery charge voltage is temperature compensated to optimize battery

charge and life.

M‑7600 Series Protection and Control System Applications

The M‑2032B in conjunction with the M‑7600 Series includes smart battery charging

features that are a result of the Beckwith Electric proprietary communication protocols

employed between the M‑2032B and M‑7600 Series utilizing a SATA cable connected

via the Aux I/O port on the M‑7600 Series. The following features are provided when

a M‑2032B is connected to a M‑7600 Series:

• Receives commands to:– Turn‑on/off battery test load– Turn‑on/off 13.8 Vdc

accessory supply– Turn battery supply off 

• Communicates the following to the M‑7600 Series:

– Charger state

– Main power supply status

– Battery Voltage

– Battery Current

– Recloser Gas Pressure (if recloser is equipped with sensor)

• Includes a Wakeup system that is initiated by the local panel pushbutton.

Turn-on/off Battery Load Test Command

M‑2032B Battery Charger/Power Supply – Specification

The M‑7600 Series issues the "Turn‑on/off Battery Load Test" command to the

M‑2032B to test the battery capacity when the unit is operating from the main

power supply.

Turn-on/off 13.8 Vdc Accessory Supply (Aux Power)

The accessory supply provides power for external devices such as radio,

modems, etc. When the M‑2032B is used in conjunction with the M‑7600

Series, the 13.8 Vdc output can be enabled/disabled utilizing the control's

HMI, IPScom, or communication protocols.

Turn Battery Supply Off Command

When the battery voltage decreases to less than a level set by the user, the

battery supply to the M‑7600 Series will be turned off (Sleep Mode) to protect

the battery. Discharging batteries below certain levels will shorten the life of

or damage the battery.

Wakeup System Command

The Wakeup system command is initiated by the M‑2032B local panel pushbutton.

  • Beckwith Electric B-2355 Adapter Kit
  • Beckwith Electric B-2203 Adapter Kit
  • Beckwith Electric B-2271 Adapter Kit
  • Beckwith Electric B-2293 Adapter Kit
  • Beckwith Electric B-6200A-U1 Hinge Kit
  • Beckwith Electric M-2032B Battery Charger/Power Supply
  • Beckwith Electric M-2900A Tapchanger Control Cabinet
  • Beckwith Electric M-6200A Digital Voltage Regulator Control
  • Beckwith Electric M-0124 Surface Mounting Adapter
  • Beckwith Electric B-2048 Resistor Assembly
  • Beckwith Electric M0169A Auxiliary Current Transformer Units
  • Beckwith Electric M-0121 and M0169A Auxiliary Current Transformer Units
  • Beckwith Electric M-0404 Voltage Isolation Transformer
  • Beckwith Electric M-0329B LTC Backup Control
  • Beckwith Electric M-0001 Battery Transient Suppressor
  • Beckwith Electric Module d’Équilibrage en Parallèle M-0115A
  • Beckwith Electric M-0115A Parallel Balancing Module
  • Beckwith Electric M-2025D Current Loop Interface Module
  • Beckwith Electric M-0362 Voltage Isolation Transformer
  • Beckwith Electric M-2025B Current Loop Interface Module
  • Beckwith Electric M-2174B Adapter Panel
  • Beckwith Electric M-2027 AC to DC Backup Power Supply
  • Beckwith Electric M-2054 Surface Mount Kit
  • Beckwith Electric M-2067B Adapter Panel
  • Beckwith Electric M-2270B Adapter Panel
  • Beckwith Electric M-2050 Surface Mounting Kit
  • Beckwith Electric M-2230 Adapter Panel
  • Beckwith Electric M-2052 Connection Harness
  • Beckwith Electric M-2051 Connection Harness
  • Beckwith Electric M-2279D Adapter Panel
  • Beckwith Electric M-2053 Adapter Panel
  • Beckwith Electric M-2339 Adapter Panel
  • Beckwith Electric M-2948 Tap Position Sensor
  • Beckwith Electric M-3425A Comprehensive Generator Relay
  • Beckwith Electric M-0193B Syncrocloser® Unit
  • BECKWITH ELECTRIC M-3425A Generator Prothection
  • Beckwith M-3425 Integrated Generator Protection
  • GE XAMP-1-1-2-0-0 XAMP Preamplifer
  • Honeywell 8-Node Enhanced Micro TDC 3000
  • Beckhoff ELM3142-0000 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3104-0030 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3104-0020 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3104-0000 | EtherCAT Terminal, 4-channel analog input, current
  • Beckhoff ELM3102-0120 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3102-0100 | EtherCAT Terminal, 2-channel analog input, multi-function
  • Beckhoff ELM3102-0030 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3102-0000 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff ELM3004-0030 | EtherCAT Terminal, 4-channel analog input, voltage
  • Beckhoff ELM3004-0000 | EtherCAT Terminal, 4-channel analog input, voltage
  • Beckhoff ELM3002-0425 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0405 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0325 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0305 | EtherCAT Terminal, 2-channel analog input, voltage
  • Basler Electric SBO222 Excitation Support System
  • Basler Electric SBO221 Excitation Support System
  • Basler Electric 9488800100 AVC Sensing Module
  • Basler Electric 36T865-2 BE03752001
  • Basler Electric BE1-25 BE1-25/79TR CONTROL SYNC-CHECK RECLOSING RELAY
  • Basler Electric M-300 149D940G02 POWER SUPPLY T159095
  • Basler Electric PCB CONTROL BOARD 9261402111 9346000033 S050105
  • Basler Electric BE 28053-002 Transformer BE28053002
  • Basler Electric BE3-GPR GENERATOR PROTECTIVE RELAY
  • Basler Electric VAR POWER FACTOR CONTROLLER MODEL SCP-250-G-60 P/N 9 1100 00 109
  • Basler Electric BE3-32-1S1N1 Reverse Power Relay - 277v, 5A
  • Basler Electric BE03303001 VOLTAGE TRANSFORMER
  • Basler Electric BE3-GPR-P1BVSF GENERATOR PROTECTIVE RELAY
  • Basler Electric BE1-60 VOLTAGE BALANCE RELAY T176884
  • Basler Electric 9022900-103 6-7VA 60HZ
  • Basler Electric BE1-59-A4E-E1K-B1S3F / BE159A4EE1KB1S3F Over Voltage Relay
  • Basler Electric KR2FF-M Voltage Regulator 9 1163 00 103
  • Basler Electric BE1-81-O/UT3ED1JB6N0F / BE181OUT3ED1JB6N0F
  • Basler Electric PCB Assembly 9059701100 919620
  • Basler Electric SR8A2B01A3E Static Voltace Regulator
  • Basler Electric SSR 63-12 STATIC VOLTAGE REGULATOR 600VAC 50/60HZ 9 1859 00 101
  • Basler Electric Solid State Protective Relay BE1-60
  • Basler Electric BE3-47N/27-3A4N2 9320400101 120V Phase Balance Relay
  • Automatic Voltage Regulators DECS100-B15 For Basler Electric Generator
  • Basler Electric BE1-25/ BE1-25M1GA6PN4R3F STOCK G277 Sync Check Solid State Protective Relay
  • Basler Electric BE25927001 Current Transformer
  • Basler Electric 1783 Be1783 Contactor Dc Current Transformer Coil, 1200:5A Ratio
  • Beckhoff ELM3002-0235 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0225 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0205 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0030 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff ELM3002-0000 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff EL3783-0100 | EtherCAT Terminal, 3-channel analog input, multi-function
  • Beckhoff EL3783 | EtherCAT Terminal, 3-channel analog input, multi-function
  • Beckhoff EL3773 | EtherCAT Terminal, 3-channel analog input, multi-function
  • Beckhoff EL3751-0024 | EtherCAT Terminal, 1-channel analog input, temperature
  • Beckhoff EL3751-0020 | EtherCAT Terminal, 1-channel analog input, multi-function
  • Beckhoff EL3751-0004 | EtherCAT Terminal, 1-channel analog input, temperature
  • Beckhoff EL3751 | EtherCAT Terminal, 1-channel analog input, multi-function
  • Beckhoff EL3742 | EtherCAT Terminal, 2-channel analog input, current
  • Beckhoff EL3702-0015 | EtherCAT Terminal, 2-channel analog input, voltage
  • Beckhoff EL3702 | EtherCAT Terminal, 2-channel analog input, voltage
  • CTI 2500S-27-1550 Slice I/O, RS232/485, 2DIO / 4UAI / 2AI (MATURE)
  • CTI 2500S-26-1550 Slice I/O, RS232/485, 8DIO / 2UAI
  • CTI 2500S-23-1550 Slice I/O, RS232/485, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500-RIO-A RS485 Remote Base Controller
  • CTI 2515-A 100-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2515 100-Watt AC Power Supply (MATURE - replaced by 2515-A)
  • CTI 2513-A 75-Watt DC Power Supply with Redundancy Support
  • CTI 2513 75-Watt 24VDC Power Supply
  • CTI 2512-A 75-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2512 75-Watt AC/DC Power Supply
  • CTI 2510 125 VDC Power Supply (MATURE - Replaced by 2512)
  • CTI 2559-FCAL Precision Calibration Connector
  • CTI 2596 8/16-Point DC Output Module
  • CTI 2589-A 8/16/32-Point Universal Discrete Input Module
  • CTI 2588-8 8-Point Universal Discrete Input Module (MATURED - replaced by 2589-B)
  • CTI 2585 16-Point TTL/Word Input Module
  • CTI 2582 16-Point Isolated 125 VDC Input Module
  • CTI 2581 16-Point Isolated 12-56 VDC Input Module
  • CTI 2580 16-Point Isolated 95-132 VAC Input Module
  • Basler Electric Model KT3B Voltage Regulator 2920-00-300-9212, 90 24700 101
  • Basler Electric BE1-67 Ground Directional Overcurrent Protective Relay
  • Basler Electric BE1810/U-2 Solid State Frequency Relay BE1810
  • Basler Electric 9105100106 UFOV-250A Under Freq./Overvoltage Protector
  • Basler Electric 9289902106 Circuit Board Rev A
  • Basler Electric BE1-51 SOLID STATE TIME OVERCURRENT RELAY K2EW7MA1N0F
  • Basler Electric BE3-49R-5I5A1 9320500101 TEMPERATURE RELAY
  • Basler Electric BE1-51-K1E-Z1P-A0N0F / BE151K1EZ1PA0N0F Time Overcurrent Relay
  • Basler Electric 9121000106 MANUAL VOLTAGE CONTROL
  • Basler Electric BE1-50 INSTANTANEOUS OVERCURRENT RELAY BE1-50-51B-106
  • Basler Electric STATIC VOLTAGE REGULATOR SR32A-2B15B3E
  • Basler Electric BE1-51A-K2E-W7M-B1N1A SOLID STATE TIME OVERCURRENT RELAY
  • Basler Electric SR4A2B06B3A STATIC VOLTAGE REGULATOR SR4A
  • Basler Electric 801A193F02 Hammond