Processor Communication Options
The SLC 500 processors support several communication options.
The following sections describe the available physical connections and protocol options used by the SLC 500 processors.
Physical Connection Options
Ethernet (10/100Base-T) channel offers:
• 10/100 Mbps communication rate.
• ISO/IEC 8802-3STD 802.3 (RJ45) connector for 10/100Base-T media.
• TCP/IP communication protocol.
• built-in isolation.

Heat/Cool Minimum On-times
Words 6 and 8 for channel 1
These values determine the minimum cycle time after which loop
TPO bits will turn ON. They are used to allow contactors time to close
or pull in. If the contactor is energized for less than this value, the
contactor will not close, but the attempt will count as a cycle.
For example, suppose you set the TPO period for 10 seconds and the
minimum ON time to 1 second. Then if the module calculates a CV%
of 10% or less, the TPO bit for that zone will not turn ON.

Heat/Cool TPO Period
Words 7 and 9 for Channel 1
When CV loop output is time–proportioned (TPO), use this value to
set the interval between successive turn–ONs. For less than a 100%
output level, the output goes OFF for the balance of the interval.
BASIC software works on personal computers with Windows 98, 2000,
NT, and XP operating systems. RSLinx Classic OEM software must be
installed on the personal computer in order to communicate to the
BAS module via the DH-485 interface.
Characters typed on the personal computer keyboard will be
translated and transmitted out the selected port. Information received
via the selected port will be translated and displayed in the BASIC
software client window.