Benefits
Ability to communicate directly to Ethernet Device Networks.
Use the EIOC to monitor and control Ethernet Devices.
Powerful and Scalable. The EIOC allows a huge amount of data coming from Ethernet Devices to be accessed in DeltaV,
and is scalable to fit your needs with licensing based on thenumber of devices you connect.
The EIOC can bring:
z Up to 32,000 signals from 256 Ethernet Devices when using Modbus TCP, EtherNet/IP, or IEC61850 MMS.
z Up to 30,000 signals from 64 Ethernet Devices when using OPC UA client protocol.
z Up to 2000 tags (10 signals per tag) from 256 Ethernet
Devices when using EtherNet/IP Control Tag Integration Protocol.
Monitoring. Data values integrated into the EIOC can
be used in Control Modules running inside the EIOC.
These control modules allow alarm generation,
history collection, and viewing by the operator,
as with control modules running in a Controller
using traditional DeltaV native I/O.
Supports control functionality. In addition,
function blocks allowing for discrete control and limited
PID control are supported for the EIOC. No assignment to a
controller is required. Motors, switchgear, variable frequency
drives; or any device that communicate via Ethernet
protocols can be controlled directly from the EIOC.
Easy to connect to Ethernet Devices using Modbus TCP,
EtherNet/IP, IEC61850 MMS, OPC UA client and EtherNet/
IP Control Tag Integration protocols. Use the EIOC Ethernet
protocols to connect your DeltaV system to your Ethernet
Device Networks.
Huge processing capacity. Each EIOC is capable of handling
a huge amount of Data in up to 2000 Control Modules.
EIOC is part of the DeltaV Control Network. 60 EIOC’s
can be added directly to the DeltaV Control Network,
allowing maximum freedom in segregating your networks.
Flexible networking. User configurable IP addressing for
the Ethernet Device Network allows the EIOC to be used in
almost any plant environment regardless of the networking
scheme. When designing a simplex Ethernet Device Network,
consider that the EIOC and the Ethernet Devices must be on
the same IP subnet to communicate. Also, when designing
a redundant Ethernet Device Network, consider that the
primary and secondary ports in the EIOC must be in different
subnets to follow best engineering practices.
Woodhead | SST-DNP-104-2 |/Refurbish ed
WOODHEAD SST Profibus SST-PFB-PLC5 Profibus Scanner
MOLEX WOODHEAD SST-DN3-PCI SST-DN3-PCU, DeviceNet as photo, sn:0036, toUS
Daniel Woodhead Brad Harrison 332020K04M040 Cord Set
Daniel Woodhead 27T08 Safeway Turnex Connector Pack of 9
SST Woodhead SST-ESR2-CPX-P Ethernet Modbus/Serial Modbus Comm Module
Panasonic ZUEP5491 Main Circuit Board ZUEP5480 ZUEP55201 SST Woodhead
SST/WOODHEAD ORN-PFB REV. 1.0B UNMP
430MI9W Mechanical Interlock 30A 250V Electric Welding Motor Gen Sets Compressor
Woodhead SST USC-0316 V1.6 Interface Board Module
Woodhead Molex SST-SN3-PCI-2 Network Interface Card 2 Channel
Woodhead SST-RIO-CIO Compact I/O Remote I/O Adapter
cobra AEROJET 3W-14.5 & 5W-17.5 SET Fairway Wood Head
Woodhead 1301790290 DRME7 Aero-Motive Drum Kit for EA Balancer 2.1m/7Ft
Woodhead DN11A-M200 Double-ended Cord Set, 300V 8A
WOODHEAD SST-DN3-PCI-2, DN3-PCI-1-E V1.2.8 PCI Interface Card
Jaguar XJ6 XJS Rear Shock Absorber Set Fits Jaguar XJ6 XJ12 XJS Woodhead
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved