Description
The 2595 16-Point TTL Output Module provides
sixteen TTL or CMOS compatible outputs to the CTI
2500 SeriesTM or Simatic® 505 I/O base. The
module is designed to respond to standard output
instructions. With the 2595. the PLC is capable of
providing signals to a variety of field devices
including lab instrumentation, BCD message
displays, video terminals, board level devices, and
low current annunciator panels. With an external pull
up resistor, the 2595 can interface to 24 VDC control
systems and other instrumentation. The module can
drive up to 16 CMOS or TTL loads per output.

Features
• CTI 2500 SeriesTM or Simatic® 505 Series I/O
base format
• 500V channel-to-channel isolation
• 1500 VDC channel-to-PLC backplane isolation
• Drive BCD message displays and video terminals
• High speed TTL interface to board level devices
• Interface to 5 to 24 VDC control systems and
instrumentation
• Operates as a discrete or 16 bit word output
Specifications
Inputs per module: 16 (2 outputs per common)
Isolation:
500 VDC group-to-group
1500 VDC channel-to-backplane
1500 VDC channel-to-backplane
Output Drive Capabilities:
High (VOH) (minimum) = 4.5 V @ 500 μA
Low (VOL) (maximum) = 0.4 V @ 30 mA
Rise/Fall Time = 1 μSec
Outputs are true "low" when energized
Sink Current: (maximum per output) 50 mA
PLC Reporting: X or WX (jumper selectable)
Wire gauge: 14-22 AWG removable connectors
Backplane power: 2 Watts max
Module size: Single-wide
Blown fuse indication: Front panel LED
Shipping weight:1 lb. (0.45 Kg)
Additional Product Information:
On CTI’s Website you find will links to the 2500
Series Std Environmental Specifications and the UL
Agency Certificates of Compliance .
Word and Discrete Mode
The 2595 may operate as a 16 Bit Word Output Module or as a 16
Discrete Output Module. By setting JP1 in Word Mode and using Work
shop to configure I/O the 2585 will look like a standard WX input mod
ule; for example WY1-WY8.
NOTE: The 2595 will be mapped as the first WY address (i.e. WY1). In
Word Mode Channel 1 corresponds to bit 16 or LSB and Channel 16
corresponds to Bit 1 or MSB.
In the example Figure 2. the 16-point TTL output module is inserted in
slot 1 in I/O base 0 and configured as a DISCRETE Output module
using JP1. In the example below data appears as 16 "Y" locations start
ing at "Y1". For your particular module, look in the chart for the num
ber corresponding to the slot occupied by the module. If bit locations
appear on this line, then the module is registered in the PLC memory
and the module is ready for operation.