The interface module is equipped with a PROFINET IO device interface.
This allows the B&R system (I/O modules, POWERLINK, etc.) to be connected
to systems from other manufacturers and makes it possible to quickly and easily
transfer data in both directions.
The interface module can be operated in the X20 controllers or in the expandable
X20BC1083 POWERLINK bus controller.
The interface is equipped with 2 RJ45 connections. Both connections result in an
integrated switch. This makes it easy to implement daisy chain cabling.

Ethernet and USB are onboard. In addition, the CPU has a POWERLINK connection
for real-time communication. The only differences from the X20CP3486 are that
the X20CP1486 only has one slot for interface modules and a smaller width.
The module has a compact size and combines a power measurement module that has
special features with a synchronization unit that is able to meet all demands.
The measurement unit's 3 current inputs are suitable for both X: 1 A and X: 5 A current
transformers. Overcurrent resistance and the high resolution of the measurement unit
round off its features. For the voltage inputs, the value range can be configured between
480 VAC and 120 VAC.
The area of use includes 4-wire AC networks with a phase voltage up to 480 VAC and
3-wire systems, whereas L2 can be grounded (V-connection). The module can also handle
Aron measuring circuits.
The resulting measured values include the pure phase current; line-to-line voltage or phase
voltage; the effective, reactive and apparent power parts; the mains frequency; the power
factor and much more. In addition, peak values and energy meters are stored on the module
in nonvolatile memory. Depending on the configuration, it is also possible to use a digital
output as a pulse encoder for an external energy meter.
The synchronization unit doesn't just take the phasing and phase voltage into consideration;
integrated intelligence also monitors the rate of change and other parameters, allowing them
to influence when the synchronization output is switched. It is also possible to monitor a
generator using a large number of additional conditions. A total of 4 voltage inputs provide
substantial overall flexibility.
B&R 3AM050.6 2005 analog mixed module |
B&R 4PP035.0300-01 Operation Panel PLC Module |
X20AI4622 B&R PLC module |
B&R X20CM0985 brand Programmable Logic Controller Module X20CM0985 |
X20AI4632 B&R PLC module |
Brand X20IF10G3-1 B&R Programmable Logic Controller Module X20IF10G3-1 |
B&R X20CP3585 brand PLC Module X20CP3585 |
B&R Compact CPU Module X20CP0411 Controll Unit Module X20 CP0411 |
Delivery Quickly B&R plc 3AT660.6 |
B&R X20CP1684 CPU Module |
B&R 7XX419L.50-1 brand Programmable Logic Controller Module 7XX419L.50-1 |
X20IF1030 B&R PLC Controller Module |
B&R 4PP035.0300-01 Operation Panel PLC Module Communication module |
B&R X20 SO 6300 PLC Module |
B&R X20CP1382 PLC control module X20 CP 1382 |
B&R X20CP1382 brand Programmable Logic Controller Module X20CP1382 |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved