Infi-Net Interface Cable - 10 feet Manufacturers ABB Model(s) ABB Bailey Infi 90
ABB Bailey Infi 90 and Net 90
Additional Information Infi-net Interface Cable -9 feet. Used to connect INNIS01 to NTCL01, 300V,90xC, #24 AWG
Estimated Shipping Size Dimensions: 1.0" x 1.0" x 120.0" (2.5 cm x 2.5 cm x 304.8 cm)
Weight: 1 lbs 4.8 oz (0.6kg )
Tariff Code: 8544429000
Country of Origin: United States Ships from Webster NY, USA
Infi-Net Interface Cable - 10 feet
processor load
• Optical communication
• Industrial grade hardware with no moving parts
• Long life cycle, easy upgrading
• Robust reliance file system, insusceptible post power loss
07EA90-SI ABB modules are used to convert analog signals to digital signals and transmit them to the control system for monitoring and controlling industrial processes.
These accuracy settings are only used when negotiating for time mastership with
other nodes in the underlying Harmony control network.
On-board processing capabilities
The process I/O modules are “intelligent” in the sense that module-related signal and data processing is
performed on board as opposed to centrally, by the CPU of the host controller. Time tagging of events,
filtering and gain control are some examples of board-level tasks.
This functional distribution improves real-time performance and reliability of the
system as a whole and maintains processing capacity when the system is expanded.
Message Wait Period
Message wait period is the Period that Harmony Server waits before attempting to
assume time mastership on the control network. This property is used only when
Time Synchronization is enabled. The permissible values are between 180 and 3660
seconds. Additionally, the configured value must greater than the Master Update Period.
I/O SYSTEMS - SD SERIES I/O DO05
The DO05 digital output module provides16, CH-2-CH isolated electromechanical relay contact outputs.
The electromechanical relay contacts are capable of handling up to 3.0 A.
The module executes at 1 msec cycle and has an average response time of 0.5 msec based on when command is received from controller.
The DO05 module provides staple jumpers to select between NO or NC contacts.
FC 221 (I/O Device Definition) sets DO module operating parameters and each output channel is configured
using FC 225 (Digital Output CH) to set indivdual output channel parameters such as alarm state setting,
default state on loss of communication with controller, etc.
You may need the following additional products:
ABB AO01A AO module 16-CH High Level |
ABB AO02 AO module 16-CH with HART |
ABB AO02A AO module 16-CH with HART |
ABB AO05 AO Module 8-CH Galv. isol. HART |
ABB AO05A AO Module 8-CH Galv. isol. HART |
ABB BK01 Blank SD I/O Module Cover |
ABB DI01 DI module 16-CH 24 / 48 VDC SOE |
ABB DI01A DI module 16-CH 24 / 48 VDC SOE |
ABB DI02 DI02 16-CH 120 VAC / 125 VDC SOE |
ABB DI02A DI02A 16-CH 120 VAC / 125 VDC SOE |
ABB DI03 DI module 16-CH 24 VDC |
ABB DI03A DI module 16-CH 24 VDC |
ABB DI04 DI module 16-CH 48 VDC |
ABB DI04A DI module 16-CH 48 VDC |
ABB DO01 DO module 16-CH 24 / 48 VDC max 250mA |
ABB DO01A DO module 16-CH 24 / 48 VDC max 250mA |
ABB DO02 DO module 16-CH 24 / 48 VDC OC Prot. |
ABB DO02A DO module 16-CH 24 / 48 VDC OC Prot. |
ABB DRMP-19 DIN-Rail Mtg Panel 19 inch Generic HW |
ABB DRMP-19SD DIN-Rail Mtg Panel 19 inch SD Series |
ABB HAI805 Analog Input Module 8-CH HART |
ABB HAI805A Analog Input Module 8-CH HART |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
wechat/whatsapp:
+86-181-4410-0983
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved