Introduction
The DeltaV SIS™ process safety system has a uniquely scalable modular architecture that is based on the CHARMs
Smart Logic Solver (CSLS) and the unprecedented flexibility and ease of use of the Emerson Electronic Marshalling solution.
Each CSLS provides I/O processing, Safety Integrity Level 3-capable logic solving, and diagnostics in a single logic solver.
The CSLS supports up to 96 local individually configurable channels, allowing flexibility for implementing safety
instrumented functions and is designed specifically for multi-core home run cables or field junction box installation.
All communications are completely redundant from the channel (LS CHARM) to the CSLS. Integrated HART® I/O
brings field diagnostics into the CSLS.

Benefits
Optimized process reliability: Emerson has extended DeltaV Electronic Marshalling technology to safety instrumented systems,
with DeltaV SIS being a key component of the Smart SIS Solution.
Research shows that more than 90% of all faults in SIS applications occur in field instruments and final elements.
The DeltaV SIS process safety system has the world’s first Smart Logic Solver using LS CHARMs.
It communicates with intelligent field devices using the HART protocol to diagnose faults before they cause spurious trips.
This approach increases process availability and reduces lifecycle costs.
Flexibility to meet project needs: Whether you have an isolated wellhead or a large emergency shutdown
(ESD) application, the DeltaV SIS system scales to provide you with the safety coverage you need for your SIL 1, 2,and 3 safety functions.
Each CHARMs Smart Logic Solver provides I/O processing, SIL 3-capable logic solving, and diagnostics.
This means that processing power is added as the system expands.
If the I/O limit is reached, a CSLS is added increasing memory and processing capacity along the additional I/O.
This allows for I/O scalability without impacting the scan rate.
Modularity also provides isolation of safety instrumented functions (SIF).
This isolation eliminates single-points of failure for improved availability and safety integrity.
DeltaV SIS components can be added online to facilitate system expansions.
Woodhead SST SD -PCI-U
MOLEX WOODHEAD DEVICENET SST-DN4-PCI SST-DN4-PSU V2.0.2 INTERFACE CARD
SST Woodhead 5136-DNP-ISA-2 DeviceNet Pro ISA Two Channel Board
WoodHead Cord Reel & Lamp SET 3778 832722FU-09 DANIEL WOOD HEAD
Woodhead SST ControlNet Card CN-104-E
AMAT 0190-16926 REV. 001 SST woodhead DNet bus scanner DNPCPCI3U1-NC- 3V V1.3.4
WoodheadSST-PF B-CLX PROFIBUS DP Remote I/O Scanner Module
Woodhead Canada Limited / SST 5136-DNP-PCI DeviceNet Pro PCI Adapter
Woodhead | SST-DNP-104-2 |/Refurbish ed
WOODHEAD SST Profibus SST-PFB-PLC5 Profibus Scanner
MOLEX WOODHEAD SST-DN3-PCI SST-DN3-PCU, DeviceNet as photo, sn:0036, toUS
Daniel Woodhead Brad Harrison 332020K04M040 Cord Set
Daniel Woodhead 27T08 Safeway Turnex Connector Pack of 9
SST Woodhead SST-ESR2-CPX-P Ethernet Modbus/Serial Modbus Comm Module
Panasonic ZUEP5491 Main Circuit Board ZUEP5480 ZUEP55201 SST Woodhead
SST/WOODHEAD ORN-PFB REV. 1.0B UNMP
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
Email: kongjiangauto@163.com
Copyright © 2009 - 2024 Cld , All Rights Reserved K-JIANG All rights reserved