The ELX3204 analog input terminal allows the direct connection of RTDs
located in hazardous areas classified zone 0/20 or 1/21.
The circuitry of the ELX3204 can operate sensors with 2-wire technology.
Linearization is carried out over the entire freely selectable temperature
range. By default the terminal is set to Pt100 sensors with 2-wire
technology. The ELX3204 terminal indicates signal state and sensor
malfunctions (e.g. wire breakage) by means of LEDs.

EtherCAT terminals of the ELX series must always be operated in conjunction
with the ELX9560 power supply terminal. This terminal generates an
electrically isolated output voltage (24 V EX) from the input voltage (24 V DC)
for supplying the subsequent ELX terminals. If a new power supply is required,
the combination of an ELX9410 and an ELX9560 can be used so that further
ELX terminals can be added.
The ELX terminal segment must be terminated with one ELX9012. two ELX9410
or one EK1110. The use of two ELX9410 allows the use of EL terminals behind
ELX terminals. With the EK1110. the terminal segment can be continued via an
EtherCAT cable, for example to implement cable redundancy.
The ELX318x analog input terminal allows the direct connection of
intrinsically safe HART-capable field devices located in hazardous
areas classified zone 0/20 or 1/21. It supplies measuring transducers
located in the field and transmits their analog measuring signals
electrically isolated to the automation device.
Overload and open-circuit detection are signaled by the error LEDs,
furthermore LEDs inform about the status of the HART communication
and signal any communication errors. The EtherCAT Terminal indicates
the signal state by means of light emitting diodes.
The HART protocol (Highway Addressable Remote Transducer) enables
two-way communication through digital data transfer via the analog
4…20 mA wiring. In this way, in addition to the analog current signal,
further data can be exchanged with the field device via the
superimposed digital signal.
The HART communication can also be used for the FDT/DTM concept.
The TwinCAT FDT container enables the integration of field device
DTMs into TwinCAT Engineering, so that the device configuration and
diagnostic functions are available directly within the development
environment. As the FDT concept only supports 32-bit, it cannot be
used in the 64-bit TwinCAT XAE Shell.
The ELX3152-0090 analog input terminal allows the direct connection of
intrinsically safe field devices located in hazardous areas classified zone
0/20 or 1/21. It supplies measuring transducers located in the field and
transmits their analog measuring signals electrically isolated to the
automation device. The measuring range can be switched between 0...20
mA and 4...20 mA by software.
With a technical measuring range of ±107% of the nominal range, the
terminal also supports commissioning with sensor values in the limit range
and evaluation according to NAMUR NE43. The error LEDs indicate an
overload condition and wire breakage. The error LEDs indicate an overload
condition and wire breakage.
With the aid of the TwinSAFE SC technology (TwinSAFE Single Channel) it
is possible to make use of standard signals for safety tasks in any network
or fieldbus. To do this, EtherCAT I/Os from the areas of analog input,
position measurement or communication (4… 20 mA, incremental encoder,
IO-Link, etc.) are extended by the TwinSAFE SC function.
The properties typical for the signals and the standard functions of the I/O
components are retained. TwinSAFE SC I/Os differ optically from standard
I/Os by a yellow stripe on the front of the housing.
Irrespective of the signal configuration, all ELM modules have the same
technological properties. The ELM360x modules for IEPE evaluation offer
a maximum sampling rate of 20.000 or 50.000 samples per second. IEPE
sensors are often connected via coaxial cables, therefore the ELM360x-0002
feature a BNC connector. The 2-pin version with push-in (ELM360x-0000)
on the other hand is ideal for industrial use where a plug is unplugged
less frequently for maintenance purposes and fast wiring is much more
important.
| EATON CORPORATION PDG33M0175VFAJ CIRCUIT BREAKER |
| XV-430-10TVB-1-10 , EATON XV-430-10TVB-1-10 |
| EATON EX 1500 RT2U UNINTERRUPTIBLE POWER SUPPLY 3400810200 |
| EATON VICKERS EEA-PAM-523-A-32 02-326001 POWER AMPLIFIER |
| Eaton Durant 5-Y-41433-406-PD-Q-U Electromechanical Counter |
| EATON CORPORATION HFD3200L CIRCUIT BREAKER |
| EATON XV-102-E6-57TVRC-10 TOUCH SCREEN PANEL, PN:153525, 24VDC 0.4A, NNB |
| EATON CORPORATION ED3150 CIRCUIT BREAKER |
| EATON GHG5124407R0001 CROUSE-HINDS SERIES INTERLOCK RECEPTACLE 1308 IP66 |
| Eaton 5990-0152 Interconnect, DI, END Station 0301-0753 Rev A 0567-0753-0001 |
| Eaton 8937-HN MTL Fiber Optic Extender, Ver-HN01, Rev- F 20V-30V Dc |
| EATON XVS-460-15 MPI-1-10 operator touch panel |
| EATON MTL E05016 DIGITAL INPUT EUROCARD E05516-2134 |
| Eaton Cutler-Hammer 1785T-PMPS-1700 92-01874-02 PanelMate POWER PRO Series 1700 |
| Eaton 9130 1KVA Marine Filter PN 1029424 Rev 002 220/230/240VAC 50/60Hz 1603 |
| Brand New Eaton 9PX2200iRT3U 2200VA/2200W Uninterruptible UPS Power Supply |
| EATON N3-630 |
| EATON CORPORATION ELC-COENETM / ELCCOENETM |
| EATON CORPORATION F809F / F809F |
| EATON CORPORATION XV-102-BE-35TQRC-10 HMI |
| EATON MP-3000 SAFETY RELAY 66D2032GX1 5A MP3000 |
| Eaton 57401-401 Strider Dual Preset Speed Controller, 115VAC, 0-3/0-10VDC Output |
| EATON S801SOFT STARTER 100 HP S801R13N3B |
| EATON HMCP400W5C MOTOR CIRCUIT PROTECTOR |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
wechat/whatsapp:
+86-181-44100-983
Email: kongjiangauto@163.com
Copyright © 2009 - 2026 Cld , All Rights Reserved K-JIANG All rights reserved